Dual inlet centrifugal fans T D A
Transcription
Dual inlet centrifugal fans T D A
Dual inlet centrifugal fans TDA 40,000 hours in standard operation. A transmission protection housing (pre-galvanised panels and electro-zinc grille) is supplied as standard. In a metal angle-bar frame, the casings are positioned in 4 different orientations (0°, 90°, 180°, 270°) each available in two directions of rotation: clockwise and anti-clockwise (see. § “Orientations – Direction of rotation” next page) depending on which side of the casing the motor is placed. APPLICATION These dual inlet centrifugal fans are equipped with impulse impellers (forwards curved blades). They are designed to transfer large flows at medium and low pressures, and can be used to transport clean air at a maximum temperature of +40°C. DESCRIPTION The casing is made of pre-galvanised sheet steel. OPTIONS Pre-galvanised steel impellers are statically and dynamically balanced: class G6.3 in accordance with standard ISO 1940. ►epoxy paint ►special low temperature assembly (-30°C) ►dual or triple versions ►chassis mounting for large drive units Depending on the application, the motors supplied as standard have a 230/400V or 400/690V supply voltage. Degree of protection IP55, Temperature class F. The bearings are fitted with self-aligning ball-bearings with eccentric ring shaft locking with a design working life of about CENTRIFUGAL S DIMENSIONS A B C E H 7/7 295 330 209 232 9/9 355 404 265 10/10 402 452 12/12 475 15/15 J K L M P S V X1 X2 ØR 315 150 280 478.5 258 6 24 220 255 10 298 380 150 346 536 323 6 24 280 327 10 290 326 432 150 374 574 350 6 24 326 377 10 534 342 386 505 150 444 644 416 6 29 384 443 10 553 622 404 473 585 150 532 732 504 6 29 460 531 10 18/18 666 754 480 556 700 150 626 826 592 6 35 553 641 10 20/20 795 935 604 602 840 150 682 927 642 6 40 595 735 12 22/22 863 1019 695 655 908 150 735 980 695 6 40 663 819 12 25/25 953 1142 794 765 998 150 845 1090 805 6 40 753 942 12 30/28 1159 1374 933 890 1204 150 970 1250 930 6 40 959 1174 12 DEPENDING ON DRIVE TYPE AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 109 Catalogue 2008 Edition Dual inlet centrifugal fans TDA ORIENTATION – DIRECTION OF ROTATION LG 0 LG 90 LG 180 LG 270 RD 0 RD 90 RD 180 RD 270 CENTRIFUGAL S POSITIONS OF MOTORS ABOUT ORIENTATIONS For centrifugal fans, whether with single or dual air inlet, the convention states that orientations take the motor side (direct action) or the transmission side as a reference. If the impeller rotates in a clockwise direction (or “to the right”) its direction will be RD; if it rotates in and anti-clockwise direction its direction will be LG. - CONSTRUCTIONS The position of the motor will depend on the space available for location of the fan. To designate the appropriate position, specify the orientation (LG or RD) followed by the following motor position number: - - N IER CT 1 2 3 4 5 6 1 2 3 4 5 6 DUAL OR TRIPLE CONSTRUCTION Please contact us AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 110 Catalogue 2008 Edition Dual inlet centrifugal fans TDA 1 COMPANION FLANGE AT DISCHARGE A B a b 7/7 260 282 210 232 9/9 315 348 265 10/10 340 376 12/12 392 15/15 vxt zxt y x Ød L 1x125 1x125 55.5 66.5 8 25 298 1x125 1x125 83 99.5 8 25 290 326 1x125 1x125 95.5 113.5 8 25 436 342 386 1x125 1x125 121.5 143.5 8 25 452 524 402 474 1x125 3x125 151.5 62.5 8 25 18/18 530 590 480 540 3x125 3x125 65.5 95.5 8 25 20/20 684 682 604 602 3x125 3x125 134.5 133.5 12 40 22/22 774 735 694 655 5x125 3x125 54.5 160 12 40 25/25 875 845 795 764 5x125 5x125 105 90 12 40 30/28 1014 968 934 888 7x125 5x125 49.5 151.5 12 40 CENTRIFUGAL S ACCESSORIES 1 2 Textile component between two strips of thin panel shaped to match the sleeve and riveted or screwed onto the latter. Factory installed it is fixed in place using self-tapping screws. 2 3 FLEXIBLE SLEEVE AT DISCHARGE ANTI-VIBE MOUNTS LOAD/MOUNT (KG) A B d 25 24 76 8,5 Ø80 110 27 100 8.2 Ø100 160 28 124 10 Ø150 250 39 182 12 Ø60 3 AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 111 Catalogue 2008 Edition Dual inlet centrifugal fans TDA ACCESSORIES (cont) 4 INSPECTION HATCHES Above These are used to allow cleaning of the fan and of the internal walls of the casing. Included on request at the four positions indicated in the diagram below, they are fixed in place using self-tapping screws. Upper rear 4 Front Lower rear CENTRIFUGAL S 5 - - N IER CT Provided for the removal of condensation and of water used in cleaning the equipment, it is made up of an M10 diam. insert plugged with a bolt attached to the bottom part of the casing. If necessary, a hose can extend this device to connect to pipework. For factory installation, the fan orientation must be specified 5 6 VENT HOLE AIR INLET GRILLES These are 2 half-grilles to be fitted using self-tapping screws directly onto the sides of the casing. 7 6 RUN/STOP SWITCH Accessory fitted pre-wired. 7 8 8 MOTOR COVER Provides protection of the motor against rain and any other spays, it is fixed directly on the transmission housing. AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 112 Catalogue 2008 Edition
Documents pareils
Single inlet centrifugal fans VRD
The motors supplied as standard have, depending on the application, 230/400V or 400/690V supply voltages. IP55 degree of
protection. Temperature class F.
The bearings are equipped with self-alignin...