Single inlet centrifugal fans VRD
Transcription
Single inlet centrifugal fans VRD
Single inlet centrifugal fans VRD APPLICATION These single-inlet centrifugal fans are equipped with impulse impellers (backwards included blades). They are designed to handle high flows at low and medium pressures. F400 Homologated in accordance with standard EN 12101-3 (CTICM homologation no. CE 1166-CPD-0079), they are suitable for fume-extraction of car parks or service areas. DESCRIPTION The casings, made of pre-galvanised sheet steel, are equipped with a connection sleeve at the inlet and a flange at the discharge. The paint-finished steel impeller is statically and dynamically balanced and classified as G6.3 in accordance with standard ISO 1940. The motors supplied as standard have, depending on the application, 230/400V or 400/690V supply voltages. IP55 degree of protection. Temperature class F. The bearings are equipped with self-aligning ball-bearings with eccentric ring shaft locking and have a design working life of approximately 40,000 hours in standard operation (other than fume extraction). A transmission protection housing (pre-galvanised panels and electro-zinc grille) is supplied as standard. Housed in a metal angle-bar frame, the casings are positioned in 4 orientations (0°, 90°, 180°, 270°) each available directions of rotation: clockwise and anti-clockwise (see next page. § “Orientations – Direction of rotation”). in two CENTRIFUGAL S OPTIONS ►epoxy paint ►special low temperature assembly (-30°C) DIMENSIONS 400 500 630 710 800 900 1000 A 651 800 999 1121 1255 1408 1541 B 736 918 1157 1303 1460 1648 1810 C 38 50 53 63 74 89 90 D 4.5 5 6 7 7 7 9 E 507 638 801 898 1007 1130 1267 F 256 322 404 453 507 569 638 G 296 372 454 503 557 619 688 H 336 402 504 553 607 669 738 J 355 530 530 630 710 800 900 K 609 748 940 1050 1181 1319 1451 ØP 13x18 13x18 13x18 17x22 17x22 17x22 17x22 L max 400 500 630 710 800 900 1000 a 312 378 460 509 563 625 694 b 563 694 857 954 1063 1186 1323 c 90 90 90 180 180 180 180 d 98 131 172 151.5 178.5 209.5 244 e 200 250 300 400 500 600 700 f 168.5 209 265.5 264 268.5 280 298 g 80 80 80 120 120 120 120 h 50 50 50 50 50 50 50 n 8 8 8 8 12 12 12 Øp 9 9 9 9 9 9 9 Ør 438 541 674 751 837 934 1043 Discharge outlet DEPENDING ON DRIVE Inlet AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 39 Catalogue 2008 Edition Single inlet centrifugal fans VRD ORIENTATION – DIRECTION OF ROTATION REMINDER ABOUT ORIENTATIONS For centrifugal fans, whether with single or double inlets at the suction side, the convention states that orientations take the motor side (direct action) or transmission side as a reference. If the impeller rotates in the clockwise direction (or “to the right”) its direction will be RD; if it rotates in the anti-clockwise direction its direction will be LG. LG 0 POSITIONS LG 90 OF MOTORS LG 180 LG 270 RD 0 RD 90 RD 180 RD 270 - CONSTRUCTIONS CENTRIFUGES The position of the motor will depend on the space available during the location of the fan. To designate the appropriate position, specify the orientation (LG or RD) followed by the following motor position number: 1 2 3 4 5 6 ACCESSORIES 1 L 400 400 500 400 630 400 710 450 800 500 900 1 2 SCREEN WITH GRILLE AT DISCHARGE 1000 640 COMPANION FLANGE AT DISCHARGE LC 400 to 1000 30 2 3 FLEXIBLE SLEEVE AT DISCHARGE LMR 400 to 1000 195 3 AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 40 Catalogue 2008 Edition Single inlet centrifugal fans VRD ACCESSORIES (cont) 4 FLEXIBLE SLEEVE AT AIR INTAKE The equipment is supplied equipped with a companion flange at the inlet whose diameter matches that of the impeller (model size) to receive the textile F400 approved connection sleeve, fixed using a supplied collar. 4 5 INLET COMPANION FLANGE (with or without joggling) LM 400 to 1000 65 Used to connect the fan upstream of the flexible hose. A second fixing strap is required (not supplied). 6 CENTRIFUGAL S 5 RUN/STOP SWITCH Accessory fitted pre-wired. 6 7 MOTOR COVER Provides protection for the motor against rain and against any other spays. It is fixed directly on the transmission housing. 8 8 ANTI-VIBE MOUNTS 7 LOAD/MOUNT (KG) A B d Ø60 25 24 76 8,5 Ø80 110 27 100 8,2 Ø100 160 28 124 10 Ø150 250 39 182 12 Generally supplied in quantities of four units. WEIGHT OF VRD ACCORDING TO HEIGHT OF MOTOR SHAFTS KG 400 500 630 710 800 900 1000 80 21 30 - - - - - 90 24 33 46 59 82 100 125 100 33 43 53 71 93 109 135 112 - 45 55 73 95 111 137 132 - 80 90 108 130 146 172 160 - - - - 156 172 197 180 - - - - - 186 212 200 - - - - - - 224 WARNING! These mean values are given only as an indicator based on motors whose frames are made of aluminium. AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 41 Catalogue 2008 Edition Single inlet centrifugal fans VRD ASSEMBLY ON CHASSIS CENTRIFUGAL S In the event that a motor may not be adequately supported by the fan frame alone, chassis mounting is preferred. This configuration is restricted to standard applications excluding fume extraction. AREM - ZI, chemin des aisières - 45500 Saint-Brisson sur Loire - Tel: 00 33 (0)2.38.36.71.05 - Email : [email protected] 42 Catalogue 2008 Edition
Documents pareils
Dual inlet centrifugal fans T D A
►dual or triple versions
►chassis mounting for large drive units