Immuno/DNA Washer 20X
Transcription
Immuno/DNA Washer 20X
PI 0150, Rev. A DCN: 2248 Effective Date: 05/03/2016 IVD For In Vitro Diagnostic Use Immuno/DNA Washer 20X Intended Use For In Vitro Diagnostic Use. Summary And Explanation 20X Immuno/DNA Washer is a concentrated wash buffer used for Immunohistochemistry and in situ Hybridization procedures. It can be used in autostainers, capillary action slides as well as manual staining procedures. Presentation 20X Immuno/DNA Washer contains a buffer solution, Tween 20 detergent and a non-sodium azide anti-microbial. It is provided in liquid form. Availability Catalog No. BSB 0149 BSB 0150 Storage Store at room temperature Protocol Suggested protocol on reverse Volume 20X 20X Volume 200 mL 1000 mL Stability 3 years Preparation of Working Solutions For working solution, dilute the concentrated 20X Immuno/DNA Washer with distilled or deionized water 1:20 (50 mL of the 20X Immuno/DNA Washer diluted with distilled or deionized water to make up 1 L of 1X working solution). Recommended Protocol Use the 1X working solution during any step that requires rinsing of slides. Abbreviated Immunohistochemical Protocol Step Peroxidase/AP Blocker Primary Antibody 1st Step Detection 2nd Step Detection Substrate-Chromogen Counterstain Precautions ImmunoDetector AP/HRP 5 minutes 30 - 60 minutes 10 minutes 10 minutes 5 - 10 minutes Varies PolyDetector AP/HRP 5 minutes 30 - 60 minutes 30 - 45 minutes Not Applicable 5 - 10 minutes Varies Polydetector Plus HRP 5 minutes 30 - 60 minutes 15 minutes 15 minutes 5 - 10 minutes Varies Avoid contact with eyes. Flush with large quantities of water if contact occurs. For professional users. Minimize microbial contamination of reagents. Proper handling procedures should be used. For complete recommendations for handling biological specimens please refer to the CDC document, “Guidelines for Safe Work Practices in Human and Animal Medical Diagnostic Laboratories” (1). References 1. U.S. Department of Health and Human Services: Centers for Disease Control and Prevention. Guidelines for Safe Work Practices in Human and Animal Medical Diagnostic Laboratories. Supplement / Vol. 61, January 6, 2012. Symbol Key / Légende des symboles/Erläuterung der Symbole In Vitro Diagnostic Medical Device Dispositif médical de diagnostic in vitro In-Vitro-Diagnostikum Storage Temperature Limites de température Zulassiger temperaturbereich Manufacturer Fabricant Hersteller Read Instructions for Use Consulter les instructions d’utilisation Gebrauchsanweisung beachten Expiration Date Utiliser jusque Verwendbar bis Bio SB, Inc. • 69 Santa Felicia Dr., Santa Barbara, CA 93117, USA Tel. (805) 692-2768 • Tel. (800) 561-1145 • Fax. (805) 692-2769 • E-mail: [email protected] • Website: www.biosb.com Catalog Number Référence du catalogue Bestellnummer Lot Number Code du lot Chargenbezeichnung
Documents pareils
Monosan Tween 20 (50%)
REF / Cat. No.: MON-APP198
Instructions for use
Intended use
50% diluted Tween 20 in water; no added stabilisers; for easier pipetting due to reduced viscosity.
Monosan Fixogum Rubber Cement
Fixogum Rubber Cement 50g; for sealing cover slips during longer reactions (overnight IHC or ISH).
Datasheet Blank Template - Santa Cruz Biotechnology, Inc.
2. Aza-Carmona, M., et al. 2011. SHOX interacts with the chondrogenic transcription factors SOX5 and SOX6 to activate the aggrecan enhancer. Hum.
Mol. Genet. 20: 1547-1559.