Single level pressure switch Type 760
Transcription
Single level pressure switch Type 760
ELETTROCOMANDI Single level pressure switch Type 760 Description The type 760 pressure switch consists of a moving diaphragm and disc which activate a changeover contact (snap action). The contact can be calibrated to trip and reset at the desired pressure levels, as specified in fig. 6 (diagram A). The main contact may also close a secondary creep action contact in series when it travels beyond the trip position (flood protection contact ).. The main contact may also have a safety "heating element protector" which allows resetting even if the contacts have welded on the trip side. The terminals are arranged to accept a 12,5 mm pitch connector, or alternatively rast 5 (see fig. 4). Applications The main application is to control the level of water in appliances. May also provide flood protection and heater protection. Mechanical Available with lateral spout, angular position as specified by customer (a), or with CENTRAL spout. On the lateral spout version, the cap can have an integral clip for snap-in mounting. The mounting position must be indicated on the customer's drawing as it has an influence on calibration. Mounting The pressure switch may be snapmounted onto a steel or plastic panel or using a bracket and 3,5x11 mm selftapping screws. Electrical characteristics MAIN CONTACT Max voltage: Resistive load max: Motor load max: 250 VAC 16 A 4A FLOOD PROTECTION CONTACT Max voltage: 250 VAC Resistive load max: 1A Motor load max: 1A Frequency: 50-60 Hz Duty: Frequent Contact clearance: µ (<3 mm) Max pressure: 5.000 PA Max ambient temp.: 85°C max Dielectric strenght between terminals and support: >2,75 KV (1 min) Resistance between terminals and support: >50 M W The terminal housing is made from plastic resistant to GLOW-WIRE TEST at 850°C. The product meets the requirements of EN 60335, EN 60730-2-6 (Safety of electrical appliances) and is approved by the principal European authorities: IMQ, VDE, UTE, SEMKO, DEMKO, NEMKO, FEMKO, KEMA KEUR, ASE/SEV, BEAB, OEVE. The pressure switch can be supplied in a version which complies with UL and CSA requirements: Max voltage: 125/250 V 50-60 Hz Resistive load: 15/10 A VERS. FOR ELECTRONIC CONTROLS Max voltage: 5V Max resistive load: 5 mA HEATING ELEM. PROTECT. CONTACT Max voltage: 250 VAC Resistive load max: 0,1 A www.bitron.net - www.bitron-ind.com e-mail: [email protected] Panel mounting 12,8 TEMPLATE "A" 45° 11 TEMPLATE "B" 12.9 Panel thickness: 0.7 - 1.2 mm fig.1 Removal of device from panel With template "A", rotate the device through 90° and remove. With template "B", close the two clips using pliers and remove. ELETTROCOMANDI Stampa 11/96 Single level pressure switch Type 760 Basic single level version Spout may be LATERAL (angle a) or CENTRAL 18.8 70 10 9.7 14 Snap-in mounting clip available 12.7 12 Mounting hole Flood protection terminal Calibration screw max Ø 55 ONLY WHERE FLOOD PROTECTION CONTACT IS REQUIRED fig.2 Two level version (dimensions) The position of the terminals can be specified by the customer (angle a) 110 Ø 2.5 Ø 5.5 fig.3 All other dimensions as in fig. 2 ELETTROCOMANDI Stampa 11/96 Single level pressure switch Type 760 Rast 5 terminal version Spout may be LATERAL (angle a) or CENTRAL 70 19.25 6.5 6.4 18.8 12.3 10 9.7 14 37.5 Ø3 Mounting hole Calibration screw max ONLY WHERE FLOOD PROTECTION CONTACT IS REQUIRED SNAP-IN FIXACTION DEVICE UPON REQUEST fig.4 Terminal configurations BASIC VERSION BASIC VERSION +FLOOD PROT. TERMINAL 16 CAN BE: A) NEXT TO TERMINAL 11 B) NEXT TO TERMINAL 12 (Version B) not yet available) VERSION WITH 2 TERMINALS FOR COMMON CONTACT (11) fig.5 ELETTROCOMANDI Single level pressure switch Type 760 Diagram "A" RESET LEVEL Pa (mmH20) 1°, 2° or 3° LEVEL RANGE OF POSSIBLE FLOOD PROTECTION LEVELS FOR EACH TRIP POINT 5.000 (500) RANGE OF POSSIBLE FLOOD PROTECTION LEVELS WITH A TRIP POINT AT 3000 Pa 4.000 (400) 3.000 (300) RANGE OF POSSIBLE RESET LEVELS WITH A TRIP POINT AT 3000 Pa 2.000 (200) RANGE OF POSSIBLE RESET LEVELS FOR EACH TRIP POINT 1.000 (100) 500 (50) 500 (50) 1.000 (100) 2.000 (200) 3.000 (300) 4.000 (400) EXAMPLE: CHOSEN TRIP POINT TOLERANCE Pa (mmH20) 5.000 (500) TRIP LEVEL Pa (mmH20) 1°, 2° or 3° LEVEL FLOOD PROTECTION LEVEL TOLERANCE ± 300 (±30) ± 250 (±25) ± 200 (±20) ± 150 (±15) ± 100 (±10) ± 75 (±7.5) ± 50 (±5) 500 (50) 1.000 (100) 2.000 (200) 3.000 (300) TRIP/RESET LEVEL TOLERANCE 4.000 (400) 5.000 (500) TRIP LEVEL Pa (mmH20) fig.6 BITRON Industrie S.p.A. Marketing & Sales Activities BITRON Ind. Marketing Deutschland Gmbh Elektrotechn. Vertrieb Bismarkstrasse,11 - D-61169 Friedberg Tel. (49) (6031) 60040.1/2 Fax (49) (6031) 600435 BITRON Ind. Marketing France 26 Avenue de la Chataigneraie 92500 Rueil Mailmaison Tel. (33) (3) 55471680 Fax (33) (3) 47520659 BITRON Ind. Marketing España Calle ifni 24-30 08930 San Adrián de Besós Barcelona (España) Tel. (34) (93) 4620159 Fax (34) (93) 4620283 BITRON Industrie S.p.A. Appliance Division: Via De Amicis, 78 10097 Borgata Paradiso - Collegno (TO) Tel. (39) (011) 4102.570 Fax. (39) (011) 4102.585 Automotive Division: Strada del Portone, 95 10095 Grugliasco (TO) Tel. (39) (011) 4029.111 Fax. (39) (011) 4029519 BITRON Ind. Marketing Latinamerica Estrada Aldeia da Serra, 711 Itaqui 06696-050 Itapevi São Paulo (SP) - Brasil Tel. (55) (11) 47898250 Fax (55) (11) 47898255 BITRON Ind. Marketing USA Automotive Tel. (001) (248) 960.6427 Fax (001) (248) 960.6455 Appliance Tel. (001) (317) 842.8583 Fax (001) (317) 842.8547 ELETTROCOMANDI Via De Amicis, 78 10097 Borgata Paradiso - Collegno (TO) Tel. (39) (011) 4102.1 Fax. (39) (011) 4102269 - 4102265 e-mail: [email protected] www.bitron.net - www.bitron-ind.com e-mail: [email protected]
Documents pareils
Tarifs Abonnements - Parcs de Stationnement de Rueil
Forfaits de courtes durées
Hebdomadaire 24/24
Abonnements 24h/24
Mensuel 24h/24 Prélèvement
Mensuel 24h/24
Trimestriel 24h/24
Annuel 24h/24