Process field transmitter with local indicator 4
Transcription
Process field transmitter with local indicator 4
Process field transmitter with local indicator 4-20mA loop powered type: INP101 • Loop powered (isolated 4-20mA) INP101V on thermowell INP101 on thermowell INP101i inox version • Local display: 10000 points • Outside mounting IP67 protection • Explosion-proof protection IECEx and ATEX • INP101V: radial display version INP101V vertical mounting • INP101 i: 316 Stainless Steel version • HART protocol INP101V horizontal mounting INP101 (available option on all models) • FDT DTM certified HART drivers • SIL2 compliance according to IEC 61508 The INP 101 is a loop powered field indicator-transmitter. It includes in a single case, protected against harsh conditions (IP67), a programmable converter ( loop powered CNL40IG ) and a 4-digit display. FUNCTIONALITY : Temperature measure and process: - Thermocouples / platinum RTD probes - Voltage (mV), current (mA) on external shunt. Functional safety data: - SIL 2 : f = 457 fit , SFF = 95.4 % , DC = 91.8 % type B component, HFT = 0 Synoptic Signal processing: - square root extraction (on process measures) - programmable sensor breaking safety value, - programmable response time from 0.2 to 60 sec, (measure filtering function) - reverse or standard output, - measure offset adjustment, - neutralization of thermal ambient variation effects Display : - LCD liquid crystal display (STN), wide temperature (4 digits), - 10000 points resolution (physical unit display). Configuration: - Configuration by RS232 serial link (all models) (USB cable supplied separately) - Communication and configuration online with standard HART programming handheld terminal Performance / Environment - Long-term stability 0.1 %/year. - Resistant, protected against collisions and vibrations (silicon coating resin) Realization, mounting and connection - Pyrometric thermo well or pipe support mounting (default) - Protection against reverse polarity - input/output insulation (elimination of measure errors due to ground loop) - IP67 protection Version and order code : INP 101 : Aluminium box, epoxy coating, IP67, display side view INP101V : Aluminium box, epoxy coating, IP67, (the mounting must be define : Horizontal or Vertical) option /H : HART communication /ADF : ATEX or IECEX explosion-proof protection /i : 316 Stainless Steel case (IP 68) /SIL2 : SIL2 compliant model according to IEC 61508 (All options are combinable) For a direct mounting on pyrometer probe (consult us) OUTDOOR TRANSMITTER E1 90 days accuracy (20 °C +/- 2 °C) DATA SHEET CAN BE DOWNLOADED ON WWW.LOREME.FR INPUT (24bits resolution) POWER SUPPLY / OUTPUT (14 bit resolution ) TYPE RANGE ACCURACY Tc B Tc E Tc J Tc K Tc R Tc S Tc T T° Compensation 200 / 1800 °C -250 / 1000 °C -200 / 600 °C -200 / 1350 °C 0 / 1750 °C 0 / 1600 °C -250 / 400 °C -20 to 60 °C ± ± ± ± ± ± ± ± TYPE RANGE ACCURACY 13 to 40Vdc (loop powered) Current 4 / 20 mA ± 0.01 mA Load resistance to 24Vdc 550 Ohms Effect of supply voltage change 0.002 % / V Effect of load stability 0.004 % / 100 Ohms 2 °C 0.4 °C 0.4 °C 0.4 °C 1 °C 1.5°C 0.5 °C 0.3 °C 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 PT100 2, 3 wires: ± 0.3 °C RTD measure range -200 / 800°C Voltage 0 / 120 mV Current 0 / 30 mA (external shunt of 2.5 ohms) ± 0,02 mV ± 0,025 mA Response time Sampling rate ~ 200msec 6 per sec. Input impedance Sensor current (Pt100) resistance line influence > 1 MOhms 300 µA 0.3°C / 10ohms Minimum current consumption Security current <3.6 mA 3.6 ... 22mA Insulation voltage Input / Output TECHNICAL SPECIFICATIONS ZONE DE FONCTIONNEMENT 4 8 12 16 20 24 28 32 36 40 ENVIRONMENT Operating temperature Storage temperature Influence (% of full scale) Weight MTBF (IEC 62380) Life time Electromagnetic compatibility Generic standards: EN 61000-6-4 / EN 61000-6-2 EN55011 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-8 EN61000-4-11 1000 Vrms continuous -20 to 60 °C -20 to +85 °C < 0.01 % / °C 1,4 Kg (without fastening) > 2 180 000 Hrs @ 30°C > 250 000 Hrs @ 30°C meet no influence < +/- 5 % < +/- 5 % no influence < +/- 5 % group 1 / class A B EN61000-4-3 < +/- 5 % B EN61000-4-6 < +/- 5 % B A EMC 2004/108/CE B DBT 2006/95/CE WIRING AND OUTLINE DIMENSIONS: 118 Tête ADF / Explosion-proof Head XD-ADwin Alliage d'aluminium / Aluminium Alloy ( EN AC-AISi9Cu3 ) - IP 68 Revêtement Epoxy / Epoxy coating Presse Etoupe ADF Laiton Nickele / Brass Explosion-proof Cable Gland M20 ADE1F N°4 pour câble / for cable Ø 4 à 8.5 mm Vitre / Glass 130 Afficheur / Display Borne de masse / EarthTerminal 13.5 41 17 Passage calibré / Metering hole Ø 6.1 H8 Convertisseur tete de sonde montage antivibratoire / In Head Transmitter antivibratory mounting Raccord Inox 316L / 316L Ss. Connection 1/2"Gcyl (BSPP) Soudure TIG / TIG Weld Raccord Coulissant Inox 316L / 316L Ss. Sliding Connection Ø 8 mm - 1/2"Gcyl (BSPP) Raccordement Internal wiring interne 1 2 3 4 5 1 2 Tube Inox 316L / 316L Ss. Pipe Ø 8x1 mm Pt100 Chips Classe B Selon CEI 751 / Class B According to IEC 751 E2 1 2 3 4 5 + - + - Pwr +24 Vdc 3 4 5 RTD - Tc + LOREME 12, rue des Potiers d'Etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: [email protected] - [email protected] On account of the constant technologies and standards evolution, LOREME keeps the possibility to modify the specifications of the included products without notice. A A
Documents pareils
liste provisoire des participants / temporary list of
Sagem is a high-tech company in the SAFRAN Group. It is
a world or European leader in solutions and services in
optronics, avionics, electronics