1 3 4 2 2:1

Transcription

1 3 4 2 2:1
This document and drawings, sketches, and schematic drawings are the property of the NICOMATIC company. and no parts thereof may be reproduced and
used without the written consent of the owner. Law dated 11.03.1902
Exemple avec un contact mâle HF :
1
2.65
Contact central
Isolant
Bouchon
arrière
Corps
B
5.40
Coiffe de masse
C
Âme conductrice
1/ Enfiler la coiffe de masse sur le câble et
plier la tresse de masse à environ 90°.
tresse de
masse
2/ Insérer le câble et souder le conducteur
sur le contact central.
4
5
1
Dielectrique
Gaine de protection
Ø câble A
4/ Sertir la coiffe de masse avec la pince DANIELS HX3,
et monter le bouchon arrière avec l'outillage C14772.
Coiffe de
masse
Contact
central
1
2
173, rue des fougères
Tel. : +33 (0)4.50.36.13.85
Z.I. Les Bracots
Fax : +33 (0)4.50.36.11.33
F-74890 Bons-en-Chablais Web : www.nicomatic.com
Designation :
Contact HF Femelle :
Coiffe de
masse
3
Contact HF Mâle :
Âme conductrice = 1
Dielectrique =5
4
Tresse de masse
=4
Bouchon arrière
stop
tresse de
masse
âme conductrice = 1
stop Soudure
90°
Hex. E
3/ Enfiler la coiffe de masse en butée sur le corps
de manière à rabattre la tresse de masse.
Echelle/Scale
2:1
Instruction de câblage contact
HF à braser série 30
a 30/08/16 Edition original
Ind. Date Modification
V.G.
Drawn
E.M.
Checked Approved
Folder : X:\Méthodes\Documentations\Instruction catalogues\
Ref : IC30HF03
Page
1/2
A4
This document and drawings, sketches, and schematic drawings are the property of the NICOMATIC company. and no parts thereof may be reproduced and
used without the written consent of the owner. Law dated 11.03.1902
Example with male HF contact :
1
2.65
Inner contact
Insulator
Back cap
Body
B
5.40
Sleeve
C
Conductor
1
1/ Thread the sleeve on cable and bent the shield at 90°.
4
5
Dielectric
Shield
2/ Place the inner contact until stop in the body.
Insert the cable and solder the conductor onto the
inner contact.
Jacket
3/ Thread the sleeve until stop on the body so
as to bent the shield.
Ø cable A
4/Crimp the sleeve with DANIELS HX3 tool and
mount the back cap with tool P/N C14772
Inner contact
Sleeve
1
173, rue des fougères
Tel. : +33 (0)4.50.36.13.85
Z.I. Les Bracots
Fax : +33 (0)4.50.36.11.33
F-74890 Bons-en-Chablais Web : www.nicomatic.com
Designation :
3
Female HF contact :
Male HF contact :
Conductor = 1
Dielectric =5
4
shield = 4
Hex. E
Sleeve
2
Back cap
stop
Shield
Conductor = 1
stop solder
90°
Echelle/Scale
2:1
Instruction de câblage contact
HF à braser série 30
a 30/08/16 Edition original
Ind. Date Modification
V.G.
Drawn
E.M.
Checked Approved
Folder : X:\Méthodes\Documentations\Instruction catalogues\
Ref : IC30HF03(Eng)
Page
2/2
A4