Accessories: Dimensioned drawing Electrical connection CSL 710
Transcription
Accessories: Dimensioned drawing Electrical connection CSL 710
CSL 710 Switching light curtains en 03-2016/05 50128826 Dimensioned drawing 7m 18 - 30 V DC We reserve the right to make changes • DS_CSL710_en_50128826.fm Switching light curtain Beam spacings 5 / 10 / 20 / 40 mm Integrated system controller Block evaluation of 8 beam areas and 4 blanking areas Display in 5 languages for fast alignment, configuration and diagnosis 4 configurable switching outputs IO-Link interface A B C D E F G L R T Y Beam spacing (see tables) Measurement field length Power In/Out Connection to transmitter Connection to receiver M6 thread Fastening groove Profile length Receiver Transmitter Beam spacing 5mm: Beam spacing 10/20/40mm: Y = 2.5mm Y = 5mm Electrical connection IP 65 IEC 60947... IEC 60947... Accessories: (available separately) Mounting brackets/sliding blocks Complete mounting bracket sets, incl. 360° rotatable models or variants with vibration dampers Ready-made connection and interconnection cables PC configuration software Leuze electronic GmbH + Co. KG [email protected] • www.leuze.com In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 CSL 710 - 03 CSL 710 Technical data Tables Optical data Typ. operating range limit 1) Operating range 2) Meas. field length 3) Beam spacing 3) Resolution Light source Wavelength 0.2 … 9m (with beam spacing ≥ 10mm) 0.1 … 4.5m (with 5mm beam spacing) 0.3 … 7m (with beam spacing ≥ 10mm) 0.1 … 3.5m (with 5mm beam spacing) 150mm … 2960mm in increments of 80/160mm 5mm, 10mm, 20mm, 40mm See technical documentation LED (modulated light) 940nm (infrared light) Timing Response time per beam 4) Delay before start-up 30μs ≤ 1.5s Electrical data Operating voltage UB 5) Residual ripple Open-circuit current 18 … 30VDC (incl. residual ripple) ≤ 15% of UB See technical documentation Interfaces Inputs/outputs Switching output current Signal voltage active/not active Activation delay Input resistance Digital interfaces 4 pins can be configured as input or output Max. 100mA ≥ 8V/≤ 2V or not connected ≤ 1ms Approx. 6kΩ IO-Link Indicators Receiver: Green LED continuous light Green/yellow LED flashing Yellow LED continuous light Yellow LED off Transmitter: Green LED continuous light (or flashing in sync with the measurement) Green LED off Display Ready System or teach error (see technical documentation) Light path free, with function reserve Light path interrupted, object detected Ready No communication with the receiver Basic settings and status information Mechanical data Housing Optics cover Connection type Fastening Continuous-cast aluminum Plastic M12 connectors Lateral sliding block or face-mounted corner bracket Environmental data/standards Ambient temp. (operation/storage) Protective circuit 6) VDE safety class Degree of protection Light source Standards applied Certifications 1) 2) 3) 4) 5) 6) -30°C … +60°C/-40°C … +70°C 1, 2, 3 III IP 65 Exempt group (in acc. with EN 62471) IEC 60947-5-2 7) UL 508, CSA C22.2 No.14 5) 8) Typ. operating range limit: min./max. attainable range without function reserve in parallel-beam operation Operating range: recommended range with function reserve in parallel-beam operation Measurement field lengths and beam spacings specified in fixed rasters, see ordering table Cycle time = number of beams x 0.03 ms + 0.4 ms. The minimum cycle time is 1 ms. For UL applications: use is permitted exclusively in Class 2 circuits according to NEC 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, must be provided with external protective circuit for inductive loads! 7) Electromagnetic compatibility: This is a Class A product. In a domestic environment this product may cause radio interference, in which case the operator may be required to take adequate measures. 8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7) Profile length L [mm] Measurement field length B [mm] At beam spacing A [mm] 5 10 20 40 160 160 150 – 240 – – – 320 320 310 290 400 – – – 480 480 470 – 560 – – – 640 640 630 610 720 – – – 800 800 790 – 880 – – – 960 960 950 930 1040 – – – 1120 1120 1110 – 1200 – – – 1280 1280 1270 1250 1360 – – – 1440 1440 1430 – 1520 – – – 1600 1600 1590 1570 1680 – – – 1760 1760 1750 – 1840 – – – 1920 1920 1910 1890 2000 – – – 2080 2080 2070 – 2160 – – – 2240 2240 2230 2210 2320 – – – 2400 2400 2390 – 2480 – – – 2560 2560 2550 2530 2640 – – – 2720 2720 2710 – 2800 – – – 2880 2880 2870 2850 2960 – – – 168 248 328 408 488 568 648 728 808 888 968 1048 1128 1208 1288 1368 1448 1528 1608 1688 1768 1848 1928 2008 2088 2168 2248 2328 2408 2488 2568 2648 2728 2808 2888 2968 Notes Observe intended use! This product is not a safety sensor and is not intended as personnel protection. The product may only be put into operation by competent persons. Only use the product in accordance with its intended use. The functional earth must be connected to the sliding block connections. CSL 710 - 03 2016/05 CSL 710 Switching light curtains Part number code C S L 7 1 0 - T 0 5 - 1 9 2 0 . A - M 1 2 C S L 7 1 0 - R 0 5 - 1 9 2 0 . A / L - M 1 2 Operating principle CSL Switching light curtain Series 710 710 series, 7 m range, cycle time 30μs per beam, display Function T Transmitter R Receiver Beam spacing 05 5mm 10 10mm 20 20mm 40 40mm Measurement field length xxxx Measurement field length [mm], dependent on beam spacing, For values see "Tables" on Page 2 Equipment A Plug outlet axial Interface L IO-Link Electrical connection M12 M12 connector Leuze electronic GmbH + Co. KG [email protected] • www.leuze.com In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 CSL 710 - 03 CSL 710 Order guide Designation Transmitter (see type code) CSL710-T… Receiver (see type code) CSL710-R… Part no. Accessories Mounting brackets 4 sliding blocks Bracket set 360° (consisting of 2 x BT 360°) L-angle bracket set (consisting of 2 x BT-L) Z-angle bracket set (consisting of 2 x BT-Z) Mounting clamp set for mounting in device columns (consisting of 2 x BT-P40) 2 mounting brackets, 70mm long, swiveling with vibration damper, incl. 4 screws and 4 sliding blocks 2 mounting brackets, 270mm long, swiveling with vibration damper, incl. 4 screws and 4 sliding blocks 2 swiveling mounting brackets with fastening screws, swiveling from -8° to +8° 2 swiveling mounting brackets with fastening screws, swiveling from -8° to +8°, with vibration damping BT-4NC BT-2R1 BT-2L BT-2Z BT-2P40 BT-2SSD BT-2SSD-270 BT-2SB10 BT-2SB10-S 425725 429046 429056 429057 424417 429058 429049 424422 424423 Connection cables with M12 connector, 8-pin socket - open cable end Connection cable 2m, PUR sheathing Connection cable 5m, PUR sheathing Connection cable 10m, PUR sheathing K-D M12A-8P-2m-PUR K-D M12A-8P-5m-PUR K-D M12A-8P-10m-PUR 50104591 50104590 50106882 Interconnection cables between transmitter and receiver Interconnection cable 1m, PUR sheathing Interconnection cable 2m, PUR sheathing Interconnection cable 5m, PUR sheathing Interconnection cable 10m, PUR sheathing Interconnection cable 20m, PUR sheathing KDS DN-M12-5A-M12-5A-P3-010 KDS DN-M12-5A-M12-5A-P3-020 KDS DN-M12-5A-M12-5A-P3-050 KDS DN-M12-5A-M12-5A-P3-100 KDS DN-M12-5A-M12-5A-P3-200 50129779 50129780 50129781 50129782 50129783 SET MD12-US2-IL1.1 + accessories K-DS M12A-8P-4P-2m-L-PUR K-DS M12A-8P-4P-5m-L-PUR 50121098 50120999 50121000 Connection cables IO-Link accessories Programming set IO-Link USB master V2.0 + cable + power supply unit Interconnection cable CSL 710 to IO-Link master, 2m, 8-pin socket / 5-pin plug Interconnection cable CSL 710 to IO-Link master, 5m, 8-pin socket / 5-pin plug CSL 710 - 03 2016/05