PGRT Series Retrofit Kit Installation Instructions

Transcription

PGRT Series Retrofit Kit Installation Instructions
PGRT Series Retrofit Kit Installation Instructions
Jarvis Corp LED Products
2000 W. Fulton St. F321
Chicago, Illinois, 60612
Office (800) 363-1075
Fax (800) 244-3152
www.jarvislights.com
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRES WIRING, POWER SUPPLY, OR OTHER ELECTRICAL
PARTS MAY BE DAMAGED WHEN DRILLING FOR INSTALLATION OF RETROFIT ASSEMBLY HARDWARE. INSPECT
WIRING AND COMPONENTS FOR DAMAGE.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. LE CÂBLAGE DES LUMINAIRES, LES BLOCS
D’ALIMENTATION OU LES AUTRES COMPOSANTS ÉLECTRIQUES PEUVENT SUBIR DES DOMMAGES LORS DU
PERÇAGE EN VUE D’INSTALLER LA QUINCAILLERIE D’UN NÉCESSAIRE DE MODERNISATION. VÉRIFIER SI LES
CÂBLES ET LES COMPOSANTS SONT ENDOMMAGÉS.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE’S ELECTRICAL SYSTEM AND
THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED PERSON.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DE CE NÉCESSAIRE DE
MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU
SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N’EST PAS QUALIFIÉE
NE DOIT FAIRE AUCUNE TENTATIVE D’INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRES THAT HAS THE
CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND WHERE
THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE LUMINAIRE.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. N’INSTALLER CE NÉCESSAIRE QUE DANS LES
LUMINAIRES DONT LES CARACTÉRISTIQUES DE CONSTRUCTION ET LES DIMENSIONS SONT CONFORME À
CELLES ILLUSTRÉES DANS LES PHOTOS ET/OU LES DESSINS ET DONT LA PUISSANCE D’ENTRÉE NOMINALE DU
NÉCESSAIRE DE MODERNISATION NE DÉPASSE PAS CELLE DU LUMINAIRE.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other
sharp objects.
AVERTISSEMENT - Pour éviter d'endommager le câblage ou à l'abrasion, ne pas exposer le câblage des bords de
tôle ou d'autres objets pointus.
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS
DURING KIT INSTALLATION.
IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE
COMPOSANTS ÉLECTRIQUES AU COURS DE L’INSTALLATION DU NÉCESSAIRE.
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D’UN LUMINAIRE LORSQUE LA
PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR PAR LES AUTORITÉS COMPÉTENTES.
REPLACE LED LAMP ONLY WITH UL-LISTED HID LUMINAIRES OF A SHOEBOX DESIGN WITH MINIMUM
DIMENSIONS OF 12”x12”x5”.
REMPLACER LA LAMPE DEL SEULEMENT AVEC “HID LUMINAIRES” QUI ONT UNE INSCRIPTION PAR UL AVEC
Revision 1: January 2016
Jarvis Corp’s Terms and Conditions are available at www.jarvislights.com
DIMENSIONS AU MOINS 12”x12”x5”.
The PGRT series retrofit kit is to be installed into existing UL-listed HID luminaires. Existing luminaire must be of
a shoebox design and have minimum dimensions of 12”x12”x5”.
The PGRT series retrofit kit is not designed for retrofitting of up-lights. All retrofitted luminaires must be
installed so that the PGRT retrofit kit is in a downward orientation.
Before starting work:
Ensure that all electrical connections are not live! Take all steps necessary to make sure that electrical
connections will not become live accidentally during installation.
All work is to be performed by a professional electrician.
PGRT Retrofit Kit Includes:
1 unit of LED Luminaire Panel with attached driver
4pcs of panel attachment tabs (most installations)
4pcs of 6-32 machine screws (most installations)
For wet-location installations, silicone sealant must be used as part of the retrofit process. Sealant must be
105ºC rated, cURus RTV Sealant
Installation Steps:
1. Open up existing luminaire by removing screws that hold the lens-frame in place. Remove existing lamp
and reflector. Continue removing the existing HID components until all are removed. Do not remove the
grounding wires.
2. Remove existing glass from lens frame. If applicable, remove the existing mounting tabs on the back side
of the lens-frame that secure the glass in place. Save these for re-use. If the glass is secured with adhesive,
use caution while removing the adhesive. A knife may be required.
For step 2, it may be easier to unhinge the lens frame. If this is done, be sure to reattach the lens-frame in
the same manner it was originally attached.
3. Place PRGT panel into place of the existing glass, with the optical chamber oriented downwards. The
driver will be enclosed in the luminaire when the lens-frame is closed. Do not close the lens-frame yet.
Attach the PGRT panel to the existing lens-frame.
5. For wet location installations, apply a bead of RTV sealant (provided) to the back side of the LED panel
where it meets the existing fixture’s lens frame. Apply sealant to all 4 sides and ensure that RTV is forming a
complete seal between the LED panel and the existing lens frame.
6. Connect the LED driver input wires to the line voltage. Connect all of the ground wires together. Use
connectors rated for 105°Celcius. Do not disturb the wires between the LED panel and the driver output.
Black – Hot
White – Neutral
Green – Ground
7. Hinge the lens-frame upwards and close up the light fixture using the existing screws. Installation is now
complete.
Revision 1: January 2016
Jarvis Corp’s Terms and Conditions are available at www.jarvislights.com