MTD Series - Kruger Ventilation

Transcription

MTD Series - Kruger Ventilation
MTD Series
MIXED FLOW IN-LINE DUCT FAN
Mixed Flow In-Line Duct Fan – MTD Series
• Mixed Flow in-line Duct Fan-MTD series are
specifically designed for direct connection inline with industry standard diameter circular
ducting.
Dimension
MTD 100/1
• It includes the combination of a powerful motor
factory matched to a mixed flow impeller.
151
• The combination enables the MTD Series fan
82
Ø4.5
• MTD models are manufactured in tough
reinforced plastic, except models 100, 250 &
315 in steel casing and finished in tough epoxypolyester paint coating.
28
95
34
51.5
95.5
to deliver high airflow performances with
minimum noise generation against high static
pressures typically found in ducted ventilation
systems.
28
47.5
Ø 97
232
Ø 137.5
1.4 kg
• Impeller blades moulded in tough ABS plastic,
except models 250 & 315 constructed from
pressed galvanised sheet steel.
• Easy installation or maintenance with support
brackets which allow the motor and impeller
assembly to be fitted or removed without
dismantling the adjacent ducting.
MTD 100/2 - 315
J
E
Ø5.5
Kruger Ventilation Industries Pte Ltd certifies that
the MTD series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA publication 211 and AMCA publication
311 and comply with the requirements of the
AMCA Certified Ratings Program. Models MTD
100/2-6 and MTD 125-6 are not licensed by AMCA
International.
F
H
C
• MTD Series fans are fitted with direct
connection two speed motors as standard with
thermal over load protection. All motors are
suitable for speed control regulation using
electronic or auto-transformer.
• Max. operating temperature +40 ºC.
G
ØD
A
ØB
A
∅B
C
∅D
E
F
G
H
J
Kg
MTD 100/2
303
176
115
97
100
90
80
60
188
2.0
MTD 100/2-6
303
176
115
97
100
90
80
60
188
2.0
MTD 125
258
176
115
123
100
90
80
60
188
2.0
MTD 125-6
258
176
115
123
100
90
80
60
188
2.0
MTD 160
275
200
127
157
112
130
80
60
212
4.9
MTD 200
302
217
141
198
124
140
100
94
232.5
4.9
MTD 250
386
272
192
248
155
168
145
140
291
9.4
MTD 315
450
336
224
312
188
210
182
178
356
14.0
Model
All dimensions in mm.
Performance Data - 50Hz
120
Static Pressure (Pa)
60
Static Pressure (Pa)
MTD 100/2
160
MTD 100/1
80
H
40
78
76
76
20
78
L
75
78
76
0
0
20
40
60
80
100
120
77
140
80
70
67
67
L
64
0
160
0
50
100
Static Pressure (Pa)
Static Pressure (Pa)
75
H
75
66
40
63
200
70
67
100
200
Flow Rate (m3/h)
67
L
73
300
59
67
69
61
0
0
400
H
62
73
63
100
250
MTD 160
300
120
0
200
Flow Rate (m /h)
MTD 125
0
70
150
3
160
L
68
64
3
67
71
40
Flow Rate (m /h)
80
H
100
200
300
400
500
600
Flow Rate (m3/h)
MTD 200
400
MTD 250/1
600
Static Pressure (Pa)
Static Pressure (Pa)
500
300
80
79
77
80
H
200
70
73
100
L
68
200
75
300
73
82
200
H
75
L
75
100
0
0
400
400
600
75
800
72
72 75
0
1000
0
200
400
600
Flow Rate (m3/h)
Flow Rate (m3/h)
MTD 250/2
600
800
1000
MTD 315
800
Static Pressure (Pa)
Static Pressure (Pa)
500
400
77
300
74
78
H
200
76
77
100
600
80
400
200
80
78
72
L
L
72
0
0
400
800
77
1200
3
Flow Rate (m /h)
H
86
73
74
74
0
1600
0
400
800
1200
80
1600
3
Flow Rate (m /h)
- Speed (RPM) shown is nominal. Performance is based on actual speed of test.
- Performance ratings do not include the effects of appurtenances (accessories).
- Values shown are fan inlet Lw(A) sound power level for installation type D: ducted inlet, ducted outlet. Ratings include the effect of duct and correction.
2000
Performance Data - 60Hz
MTD 100/1
100
200
Static Pressure (Pa)
80
Static Pressure (Pa)
MTD 100/2-6
250
60
H
40
68
63
20
66
60
L
66
57
0
20
40
60
H
100
64
80
100
120
140
67
L
66
63
62
0
160
0
50
100
Flow Rate (m 3/h)
150
66
200
250
300
3
Flow Rate (m /h)
MTD 125-6
200
66
64
50
66
59
0
150
MTD 160
350
120
Static Pressure (Pa)
Static Pressure (Pa)
300
160
H
L
80
66
73
65
40
70
62
250
200
78
66
59
100
63
L
50
66
H
150
66
58
60
0
0
100
200
68
300
67
0
400
0
100
200
3
Flow Rate (m /h)
69
300
400
500
600
Flow Rate (m3/h)
MTD 200
500
MTD 250/1
800
700
Static Pressure (Pa)
Static Pressure (Pa)
400
83
300
H
200
78
68
L
100
78
400
83
H
300
77
200
74
400
800
1000
0
MTD 250/2
200
400
600
800
Flow Rate (m 3/h)
1200
800
Static Pressure (Pa)
Static Pressure (Pa)
1000
MTD 315
900
600
500
400
74
79
H
300
77
74
200
100
68
L
77
0
200
400
600
800
Flow Rate (m3/h)
1000
700
600
500
81
400
77
1200
1400
H
300
92
200
70
81
74
100
70
0
-
76
72
0
Flow Rate (m3/h)
700
71
L
74
600
79
100
73
66
0
200
500
70
66
0
600
72
L
0
0
400
81
72
800
1200
1600
Flow Rate (m3/h)
Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Performance ratings do not include the effects of appurtenances (accessories).
Values shown are fan inlet Lw(A) sound power level for installation type D: ducted inlet, ducted outlet. Ratings include the effect of duct and correction.
MTD 100/2-6 and MTD 125-6 are not licensed by AMCA.
2000
Technical Data
Technical Data
Model
MTD 100/1
Max Q
m3/h
Power
W
148 / 125
33 / 20
Motor
Phase
Protection
IP44
1
N°
Pole
Hz
Max
Amp
Insulation
Class
dB (A)
at 3m
RPM
2
50
0.25 / 0.15
B
58 / 56
2400 / 2150
145 / 85
31 / 21
IP44
1
2
60
0.18 / 0.13
B
45 / 37
2600 / 2100
225 / 150
44 / 27
IP44
1
2
50
0.26 / 0.18
B
50 / 44
2250 / 1800
MTD 100/2-6
250 / 185
55 / 37
IP44
1
2
60
0.26 / 0.18
B
46 / 42
2100 / 1400
MTD 125
335 / 250
49 / 33
IP44
1
2
50
0.37 / 0.26
B
52 / 42
2210 / 1900
MTD 125-6
360 / 300
55 / 39
IP44
1
2
60
0.37 / 0.26
B
51 / 40
2350 / 1900
520 / 390
55 / 48
IP44
1
2
50
0.30 / 0.22
B
48 / 41
2500 / 1850
MTD 100/2
MTD 160
MTD 200
MTD 250/1
MTD 250/2
MTD 315
-
558 / 335
68 / 52
IP44
1
2
60
0.31 / 0.23
B
49 / 38
2600 / 1600
840 / 690
115 / 94
IP44
1
2
50
0.55 / 0.41
B
55 / 48
2500 / 2150
860 / 615
170 / 109
IP44
1
2
60
0.68 / 0.51
B
54 / 46
2650 / 2000
970 / 905
130 / 101
IP44
1
2
50
0.65 / 0.39
B
54 / 51
2680 / 2400
1110/ 932
180 / 135
IP44
1
2
60
0.65 / 0.39
B
56 / 52
1450 / 1150
1270/1020
192 / 141
IP44
1
2
50
0.72 / 0.48
B
57 / 52
2420 / 1950
1295/ 885
257 / 162
IP44
1
2
60
1.00 / 0.67
B
57 / 50
2400 / 1650
1670/1315
283 / 175
IP44
1
2
50
1.30 / 0.90
B
59 / 53
2350 / 1700
1757/1188
352 / 186
IP44
1
2
60
1.50 / 1.00
B
60 / 52
2300 / 1550
Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Performance ratings do not include the effects of appurtenances (accessories).
dB(A) at 3m with ducted inlet and outlet at free field conditions. dB(A) is not licensed by AMCA International.
MTD 100/2-6 and MTD 125-6 are not licensed by AMCA.
Accessories
Grilles
Mounted at the inlet or
outlet of the fan, the grille
prevents the entry of any
foreign objects.
Back-Draft Shutter
Mounted at the outlet of
the MTD fan, the shutter
prevents the air recirculating when the fan
is not in use.
Rectangular Duct
Adapters
The adapter enables the
MTD fan to be connected
to rectangular ducting
THE
KRUGER
GROUP
• SINGAPORE
• SINGAPORE
KRUGER VENTILATION INDUSTRIES PTE LTD
KRUGER ENGINEERING PTE LTD
No. 17, Tuas Avenue 10
Singapore 639141
Tel. +65 68611577 - Fax +65 68613577
Email: [email protected]
No. 17, Tuas Avenue 10
Singapore 639141
Tel. +65 68631191 - Fax +65 68631151
Email: [email protected]
• MALAYSIA
• THAILAND
KRUVENT INDUSTRIES (M) SDN BHD
KRUGER VENTILATION IND. (THAILAND) CO. LTD
Lot 8, Jalan Perusahaan 2 Batu Caves
Industrial Area, 68100 Batu Caves Selangor
Tel. +603 61888293 - Fax +603 61898843
Email: [email protected]
1/19 Moo 2 Rama II Rd, Tasai
Mueng Samuthsakorn 74000, Thailand
Tel. +66 34-490164-9/375-6 - Fax +66 34-490170/377
Email: [email protected]
• BEIJING
• GUANGZHOU
BEIJING KRUGER VENTILATION CO. LTD
GUANGZHOU KRUGER M&E INDUSTRIES LTD
No. 1A South Industry Area
Beijing Economical and Technological
Development Area, Beijing China 100176
Tel. +86 10-67881366 - Fax +86 10-67880566
Email: [email protected]
No. 1270 Maogang Road, Huangpu
Guangzhou, P.R. China 510700
Tel. +86 20-32387634 - Fax +86 20-32387624
Email: [email protected]
• HONG KONG
• SHANGHAI
KRUGER VENTILATION (HONG KONG) LIMITED
SHANGHAI KRUGER INDUSTRIES CO. LTD
Flat B, 9/F, Yeung Yiu Chung (No.8) Industrial Building,
20 Wang Hoi Road, Kowloon, Hong Kong
Tel. +852 22469182 – Fax +852 22469187
Email: [email protected]
No. 500 Yuanguo Road, Anting, Jiading,
Shanghai 201814 P.R. China
Tel. +86 21-69573266 - Fax +86 21-69573296
Email: [email protected]
• WUHAN
• TAIPEI
WUHAN KRUGER INDUSTRIES CO. LTD
KRUGER VENTILATION (TAIWAN) CO. LTD
No. 12 Heping Tieji Industries Parden Hongshan
Economic Zone, Wuhan P.R.China 430063
Tel. +86 27- 86718165 - Fax +86 27- 86825719
Email: [email protected]
No. 157, Ping-an Rd, Hengfeng Village,
Dayuan Shiang Taoyuan County 337, Taiwan(ROC)
Tel. +886 3-3859119 - Fax +886 3-3859118
Email: [email protected]
• PHILIPPINES
• AUSTRALIA
KRUGER M&E INDUSTRIES CORPORATION
KRUGER VENTILATION (AUSTRALIA) PTY LTD
FAPI Compound, E. Rodriguez Ave.
Tunasan, Muntinlupa City, Philippines 1773
Tel. +63 2-8622891-97 - Fax +63 2-8621287
Email: [email protected]
4 Blackfriar Place, Wetherill Park
NSW 2164, Australia
Tel. +61 2-97562008 - Fax +61 2-97560808
Email: [email protected]
• INDONESIA
• INDIA
P.T. KRUGER VENTILATION INDONESIA
KRUGER M&E INDUSTRIES (INDIA) PVT LTD
Ruko Mahkota Mas Blok C No. 20
JL. M.H. Thamrin – Cikokol Tangerang 15117
Tel. +62 21-5543107/8 - Fax +62 21-5543016
Email: [email protected]
Kruger Centre, Prince Industrial Estate,
Atgaon, Shahapur, Thane, 421304, India.
Tel. +91 2527 240275/6/170 - Fax +91 2527 240075
Email: [email protected]
• KOREA
NEOMATE TECHNOLOGY & CONSULTING CO. LTD
#502, Samyeong B/D 606-4 Gurobon-Dong,
Kuro-Gu, Seoul, Korea
Tel. +82 02-2679-2052/3 - Fax +82 02-2679-2174
Email: [email protected]
KRUGER VENTILATION INDUSTRIES PTE LTD - No. 17 Tuas Avenue 10 - Singapore 639141 - Tel +65 68611577 - Fax+65 68613577
LEA045.E3
The company is always improving & developing its products, therefore the company reserve the right to make changes to the illustrated products. Certified dimension will be provided upon request.
Edition 1
Printed on Aug 06
June 2006