Sirocco - Mepamsa
Transcription
Sirocco - Mepamsa
FR Mode d’emploi et installation GB Instructions for use and installation DE Bedienungsanleitung und Einrichtung IT Istruzioni per l’uso e l’installazione E Instrucciones de instalacion e utilizacion NL NL Instructies voor het gebruik en installeren Hotte de Cuisine Cooker Hood Dunstabzugshaube Cappa Campana Dampkap Sirocco F SOMMAIRE GB CONTENTS RACCORDEMENT ÉLECTRIQUE ELECTRICAL WIRING CONSEILS D’INSTALLATIONS INSTALLATION ADVICE POSE DE L’APPAREIL FITTING THE APPLIANCE CONSEILS D’UTILISATIONS USEFUL HINTS ENTRETIEN MAINTENANCE GARANTIE ET SERVICE APRÈS-VENTE GUARANTEE AND AFTER-SALES-SERVICES REMARQUES REMARKS D I INHALT CONTENUTI NETZANSCHLUSS COLLEGAMENTO ELETTRICO MONTAGEHILFEN CONSIGLI DI INSTALLAZIONE MONTAGE DES GERÄTES POSA DELL’ APPARECCHIO NUTZUNG CONSICLI DI UTILIZZO WARTUNG UND REINIGUNG MANUTENZIONE GARANTIE UND KUNDENDIENST GARANZIA ED ASSISTENZA TECNICA WICHTIGE HINVEISE NOTE E NL SUMARIO INHOUD CONEXION ELECTRICA ELECTRISCHE BEDRADING CONSEJOS DE INSTALACION MONTAGE AANWIJZING INSTALACION DEL APARATO AANSLUITEN VAN HET APPARAAT CONSEJOS DE UTILIZACION GEBRUIKSADVIES MANTENIMIENTO ONDERHOUD GARANTIA Y ASSISTENCIA TECNICA AFTER SALES SERVICE NOTA OPMERKINGEN F Nous vous remercions de la confiance que vous nous avez accordée en choisissant un appareil de la gamme ROBLIN. Celui-ci a fait l’objet de toute notre attention dans sa conception et sa réalisation. Afin qu’il vous donne entière satisfaction, nous vous recommandons de lire avec attention cette notice qui vous expliquera comment l’installer, l’utiliser et l’entretenir dans les meilleures conditions. La présente notice d’emploi vaut pour plusieurs versions de l’appareil. Elle peut contenir des descriptions d’accessoires ne figurant pas dans votre appareil. Avec ce kit, il est possible d’installer à distance le moteur de la hotte à l’intérieur de l’habitation. L’installation devra être effectuée par un personnel qualifié en accord avec les directives réglementaires édictées par les services compétents en matière de renouvellement d’air. Le fabricant ne pourra être tenu pour responsable des dégâts résultant d’une installation incorrecte ou de sa non-conformité. 1 RACCORDEMENT ÉLECTRIQUE. • La hotte est équipée d’un cordon d’alimentation de type HO5VVF 3 x 0,75 mm² comportant une fiche normalisée 10/16 A avec système de mise à la terre. Mode de protection : classe I. Tension d’alimentation : 220-240 V mono - 50Hz / 220 V - 60Hz. Vérifier que la tension du secteur est identique aux valeurs indiquées sur la plaque signalétique à l’intérieur de la hotte • Si la hotte est raccordée directement sur le réseau sans sa fiche, un interrupteur omnipolaire avec une ouverture de contact de 3 mm doit être installé avant la hotte. Le fil de terre (Jaune / vert) ne doit pas être interrompu par cet interrupteur. 2 CONSEILS D’INSTALLATION. • Respecter le diamètre de sortie de l’appareil : la hotte ne doit en aucun cas être raccordée à un conduit de ventilation mécanique contrôlée (V.M.C.). • Lorsqu’on évacue l’air vicié dans un conduit d’évacuation, veiller à ce que celui-ci ne soit pas déjà exploité à véhiculer des gaz ou fumées provenant d’appareils alimentés par une énergie autre qu’électrique. • Positionner le plan de cuisson au plus près de l’évacuation et éviter la formation de coudes sur la gaine, afin de réduire au maximum les pertes de charges. • Dans tous les cas d’installation, veiller au bon renouvellement d’air de la cuisine. Penser à effectuer une ou des entrées d’air par une grille de section égale ou supérieure au diamètre du tuyau d’évacuation, afin de ne pas mettre la cuisine en dépression. • Prévoir une aération suffisante lorsqu’un appareil de cuisson ou autre utilise simultanément l’air ambiant de la pièce où est installée la hotte. • La dépression maximum crée dans la pièce doit être inférieur à 0.04 mbar, ce qui évite un retour de gaz de combustion. • L’appareil doit être positionné de telle façon que la fiche d’alimentation soit accessible. • Cet appareil ne doit pas être utilisé par des personnes (y compris les enfants) ayant des capacités psychiques, sensorielles ou mentales réduites, ni par des personnes n’ayant pas l’expérience et la connaissance de ce type d’appareils, à moins d’être sous le contrôle et la formation de personnes responsables de leur sécurité. Les enfants doivent être surveillés pour s’assurer qu’ils ne jouent pas avec l’appareil. 1 F 3 POSE DE L’APPAREIL. Montage et raccordement doivent être réalisés par un installateur* qualifié. (*) Le non-respect de cette condition entraîne la suppression de la garantie du constructeur et tout recours en cas d’accident. Attention: prendre bien soin d’employer les chevilles adaptées au support, se renseigner au près des fabricants, effectuer un scellement si nécessaire. La société décline toute responsabilité en cas d’accrochage défectueux dû au perçage et chevillage. Le Groupe pour Aspiration Extérieure Murale est destiné à être installé à l’extérieur, mais ne doit pas être installé à l’intérieur. Pour obtenir une installation efficace et un bon confort acoustique, il convient de prévoir une distance entre la sortie de la hotte et le moteur Mistral de 3 à 6 mètres. a)Définir l’endroit de pose de l’appareil, en fonction de l’emplacement de la hotte. b)Percer le mur à l’endroit de la pose suivant la figure n° 2. c)Dévisser les 2 écrous borgnes du couvercle de l’appareil et enlever celui-ci . d)Emboiter l’élément de longueur 300 mm du fourreau télescopique sur la buse de l’appareil. e)Passer le cordon d’alimentation dans le tube télescopique Ø 20 mm. f)Positionner l’appareil au mur et l’orienter de façon que les grilles se présentent vers le bas. g)A l’aide des vis inox et des chevilles fournies, fixer l’appareil au mur. h)Remettre en place le couvercle de l’appareil, et visser les 2 écrous borgnes. i)Sceller le fourreau télescopique, du coté intérieur.j)Effectuer le raccordement du tuyau flexible Ø 200 sur la sortie du capteur , ainsi que sur le fourreaudu Groupe pour Aspiration Extérieure. Ne pas réduire ce diamètre et minimiser la longueurnombre de coudes, afin de garantir le bon écoulement du flux d’air. k)Raccorder le cordon d’alimentation du Groupe pour Aspiration Extérieure Murale sur le connecteur 6 voies fourni, en respectant la figure n° 3. l)Connecter électriquement la fiche du cordon du Groupe pour Aspiration Extérieure Murale sur lecapteur ou la hotte sans moteur. 4 CONSEILS D’UTILISATION. • Pour obtenir une efficacité maximum d’absorption des fumées ou des vapeurs, faire fonctionner l’appareil 5 minutes environ avant et après la cuisson des aliments; La première vitesse est conseillée pour les cuissons à feu doux et pour les sauces. La deuxième pour les cuissons soutenues, grillades et friteuses. La troisième est indiquée pour les cuissons à forte émanation de graisses et vapeur. • IMPORTANT . NE JAMAIS FLAMBER DE METS AU DESSOUS DE L’APPAREIL Ne laissez jamais de flammes libres sous la hotte en fonctionnement. • 2 Les fritures nécessitent une surveillance permanente, l’huile surchauffée pouvant s’enflammer. F 5 ENTRETIEN. Déconnecter le câble d’alimentation pour toute intervention électrique. L’appareil a été conçu pour faciliter au maximum les opérations d’entretien, synonyme de bon fonctionnement et rendement de l’appareil dans le temps. • Nettoyage des filtres métalliques. Il est indispensable de procéder à un NETTOYAGE PÉRIODIQUE de ces filtres à la main (avec un détergent liquide à l’eau tiède et rinçage) ou au lave- vaisselle (tous les deux mois environ pour une utilisation normale). • Carrosserie. Nettoyer régulièrement celle-ci en utilisant des produits détergents, non abrasifs et une éponge légèrement humide. N’utilisez jamais d’éponges ou de chiffons trempés N’introduisez aucun objet, ni les mains dans l’ouverture servant à l’évacuation de l’air • Conduit d’évacuation. Vérifier tous les 6 mois le bon écoulement de l’air vicié. Observer les prescriptions réglementaires locales concernant l’évacuation de l’air vicié. • Éclairage. Avant toute intervention sur l’appareil, mettre l’interrupteur d’allumage des lampes en position éteinte. Ne pas dépasser la puissance prescrite et ne pas changer de type de lampe. 6 GARANTIE ET SERVICE APRÈS-VENTE. • En cas d’anomalie de fonctionnement, prévenez votre installateur qui devra vérifier l’appareil et son raccordement. • Dans le cas où un composant électrique viendrait à être endommagé, celui-ci ne peut être remplacé que par un atelier de réparation reconnu par le fabricant, car des outils spéciaux sont nécessaires. • Débrancher complètement l’appareil. • Exigez toujours l’utilisation de pièces de rechange d’origine. La non observation de cette prescription peut compromettre la sécurité de l’appareil. • Lors de la commande de pièces détachées, rappeler le numéro de l’appareil inscrit sur la plaque signalétique située à l’intérieur de la hotte. • Seule la facture d’achat de l’appareil fera foi pour l’application de la garantie contractuelle. Cette garantie ne couvre pas les consommables comme : - L’éclairage : lampes incandescentes, halogènes ... - Les filtres. 7 REMARQUES. Cet équipement est conforme à la norme européenne sur la basse tension 2006/95/CE relative à la sécurité électrique et aux normes européennes: 2004/108/CE relative à la compatibilité électromagnétique et 93/68 relative au marquage CE. Lorsque ce symbole d’une poubelle à roue barrée est attaché à un produit, cela signifie que le produit est couvert par la Directive Européenne 2002/96/EC. Votre produit est conçu et fabriqué avec des matériaux et des composants de haute qualité, qui peuvent être recyclés et utilisés de nouveau. Veuillez vous informer du système local de séparation des déchets électriques et électroniques. Veuillez agir selon les règles locales et ne pas jeter vos produits usagés avec les déchets domestiques usuels. Jeter correctement votre produit usagé aidera à prévenir les conséquences négatives potentielles contre l’environnement et la santé humaine. 3 GB Thank you for buying a ROBLIN product which has been manufactured to the highest quality standards to meet your requirements. We recommend you carefully read this booklet in which you will find instructions for installation, hints for use and maintenance. The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. With this kit it is possible to place the blower of the kitchen hood to a remote position inside the house. Installation of the kit must be carried out by qualified staff, following all the rules given by the relevant authorities concerning the exhaust air ducting. The manufacturer will not be liable for any damages resulting from incorrect or from improper installation. 1 ELECTRICAL • This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug. • Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm minimum contact gap on each pole. • Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. • Technical Specification: Voltage 220-240 V, single phase ~ 50 Hz / 220 V - 60Hz. 2 INSTALLATION ADVICE • It is a possible fire risk if the hood is not sited as recommended. • To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence. • Ducting • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. • If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. • The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting. • The ducting used must be made from fire retardant materials and the correct diameter must be used, as incorrect sized ducting will affect the performance of this cooker hood. • When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative pressure in the room must not exceed 0.04 mbar to prevent the fumes from combustion being drawn back into the room. • The appliance is for domestic use only and should not be operated by children or people who are infirm without supervision. • This appliance must be positioned so that the wall socket is accessible. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 3 FITTING Any permanent electrical installation must comply with the latest regulations concerning this type of installation and a qualified electrician must carry out the work. Non-compliance could cause serious accidents or injury and would deem the manufacturers guarantee null and void. 4 GB IMPORTANT - The wires in this mains lead are coloured in accordance with the following code : green / yellow : earth blue : neutral brown : live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows. - The wire which is coloured green and yellow must be connected to the terminal in the plug which is or coloured green or green and yellow. marked with the letter E or by the earth symbol - The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. - The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manufacturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a faulty hanging due to the drilling and the setting up of plugs. The Outside Wall Aspiration has to be fitted outside, but it must under no circumstances be fitted inside. To achieve efficient installation and low level of noise, it is convenient to provide a distance from 3 to 6 meters between hood outlet and mistral motor. a)Define the place of the appliance according to position of the hood or of the capteur. b)Pierce a hole in the wall at the place where the appliance is to be positioned according to figure n°2. c)Unscrew the 2 hex domed nuts of the appliance cover and remove it d)Fit the element 300 mm long of the telescopic sleeve onto the appliance flange e)Bring the power cord through into the telescopic tube Ø 20 mm. f)Position the appliance in the wall and orient it so that the gratings present themselves to the low. g)Attach the appliance on the wall using stainless-steel screws and dowels. h)Put the cover of the appliance bock in place and screw the 2 hex domed nuts. i)Seal the telescopic sleeve froon inside. j)Connect up the flexible tube diameter 200 mm to outlet of the capteur and to the sleeve of the appliance for Outside Wall Aspiration. Comply with this diameter and number of bends to the minimum, so as to ensure good air flow. k)Connect up the power cord of the appliance for Outside Wall Aspiration on the 6 - way connectorby observing figure n° 3. l)Connect the electrical plug of the cord of the appliance for Outside Wall Aspiration on the capteur oron the cooher hood without motor. 4 USEFUL HINTS • To obtain the best performance we recommend you to switch ‘ON’ the cooker hood a few minutes (in the boost setting) before you start cooking and you should leave it running for approximately 15 minutes after finishing. • IMPORTANT: NEVER DO FLAMBÉ COOKING UNDER THIS COOKER HOOD 5 GB • Do not leave frying pans unattended during use as over-heated fat and oil might catch fire. • Do not leave naked flames under this cooker hood. • Switch ‘OFF’ the electric and gas before removing pots and pans. • Ensure heating areas on your hotplate are covered with pots and pans when using the hotplate and cooker hood simultaneously. 5 MAINTENANCE Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. The cooker hood must be kept clean; a build up of fat or grease may cause a fire hazard. Casing • Wipe the cooker hood frequently with a clean cloth, which has been immersed in warm water containing a mild detergent and wrung out. • Never use excessive amounts of water when cleaning particularly around the control panel. • Never use scouring pads or abrasive cleaners. • Always wear protective gloves when cleaning the cooker hood. Metal Grease Filters : The metal grease filters absorb grease and dust during cooking in order to keep clean the cooker hood inside. The grease filters should be cleaned once a month or more frequently if the hood is used for more than 3 hours per day. To remove and replace the metal grease filters • Remove the metal grease filters one at a time by releasing the catches on the filters; the filters can now be removed. • The metal grease filters should be washed, by hand, in mild soapy water or in a dishwasher. • Allow to dry before replacing. Active Charcoal Filter : The charcoal filter cannot be cleaned. The filter should be replaced at least every three months or more frequently if the hood is used for more than three hours per day. To remove and replace the filter • Remove the metal grease filters. • Press against the two retaining clips, which hold the charcoal filter in place and this will allow the filter to drop down and be removed. • Clean the surrounding area and metal grease filters as directed above. • Insert the replacement filter and ensure the two retaining clips are correctly located. • Replace the metal grease filters. Extraction tube : Check every 6 months that the dirty air is being extracted correctly. Comply with local rules and regulations with regard to the extraction of ventilated air. Lighting : If the lamp fails to function check to ensure it is fitted correctly into the holder. If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not fit a lamp with a higher rating. 6 GUARANTEE AND AFTER SALES SERVICE • In the event of any malfunction or anomaly, notify your fitter who will have to check the appliance and its connection. • In the event of damage to the mains supply cable, this can only be replaced by at approved repair centre appointed by the manufacturer who will have the required tools and equipment to carry out any repairs properly. Repairs carried out by other persons will invalidate the guarantee. • Use only genuine spare parts. Should these warnings fail to be observed it could affect the safety of your cooker hood. • When ordering spare parts quote the model number and serial number written on the rating plate, which is found on the casing behind the grease filters inside the hood. 6 GB • Proof of purchase will be required when requesting service. Therefore, please have your receipt available when requesting service as this constitutes the date from which your guarantee commenced. This Guarantee does not cover : - Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or filters or removable parts of glass or plastic. These items are considered to be consumable under the terms of this guarantee. 7 REMARKS This appliance complies with European regulations on low voltages Directive 2006/95/CE on electrical safety, and with the following European regulations: Directive 2004/108/CE on electromagnetic compatibility and Directive 93/68 on EC marking. is attached to a product it means the product is covWhen this crossed-out wheeled bin symbol ered by the European directive 2002/96/EC.Your product is designed and manufactured with high quality materials and components, which can be recycled and reused.Please inform yourself about the local separate collection system for electrical and electronic product. Please act according to your local rules and do not dispose of your old products with your normal household waste. The correct disposal of your old product will help prevent potential negative consequences for the environment and human health. 7 Plaque Signalétique Rating plate of the cookerhood Typenschild im Inneren der Dunstesse Etichetta all'interno della cappa Etiqueta de la campana Modèle Model Modell Modello Modelo Model A1 Numéro de série Serial number Seriennummer Numero di serie Numero de serie Serienummer 1 2 A2 A3 2 1 1 3 5 1 3 5 Red Yellow Brown Blue Green-Yellow Blue 3 M 83 W LIVE - PHASE - PHASE NEUTRAL - NEUTRE - NULLEITER A - AZUR - AZUR - AZUR BLAU BK - BLACK - NOIR- SCHWARZ B - BLUE - BLEU - BLAU Br - BROWN - BRUN - BRAUN G-Y - GREEN YELLOW - VERT JAUNE - GRÜN GELB Gr - GREY - GRIS - GRAU L B - LIGHT BLUE - BLEU CLAIR - HELL BLAU P - PINK - ROSE - ROSA V - PURPLE - MAUVE - MALVER FARBIG R - RED - ROUGE - ROT W - WHITE - BLANC - WEISS W-P - WHITE PINK - BLANC ROSE - WEISS ROSA Y - YELLOW - JAUNE - GELB Maj (Update) 04/02/2013 Page 1/1 Désignation Sirocco depuis: Février 2013 (From) 3S_SIROCCO_V2013-02 Composants Components Bauelemente A5 Componenti Componentes Onderdelen UK ELECTRICAL CONNECTION The wires in this mains lead are coloured in accordance with the following code: ELECTRICAL REQUIREMENTS Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC). ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions. Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your connection unit, proceed as follows:The wire which is coloured blue must be connected to the terminal which is marked with the letter ‘N’ or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter ‘L’ or coloured red. CH Fiche de sécurité class 1, 250 V~ 10A 2 poles + terre. Stecker der Schutzklasse 1, 250 V~ 10A Zweipolig mit Schutzkontakt (Erde). Spira di sicurezza classe 1, 250 V~ 10A 2 poli + terra SEV 1011, SN416534-2, CH-Typ 12 A6 FRANKE France S.A.S. 25 Rue des Rosiers - Sainte Cécile B. P. 60056 50800 VILLEDIEU-LES-POËLES - France Tél. 02 33 91 26 50 - Fax 02 33 51 54 79 - e-mail : [email protected] For outside France : Tel. +33 (0)2 33 91 26 57 - Fax. : +33 (0)2 33 51 54 79 e-mail : [email protected] 20NO405 - 130204