ENV1991-2-5 an

Transcription

ENV1991-2-5 an
ENV 1991-2-5
EUROPEAN PRESTANDARD
PRÉNORME EUROPÉENNE
EUROPÄISCHE VORNORM
March 1997
English version
Eurocode 1 - Basis of design and actions on structures
Part 2.5 : Thermal actions
Eurocode 1 - Bases de calcul et actions sur les
structures - Partie 2-5 :
Eurocode
1
Tragwerksplanung und
Tragwerke - Teil 2-5 :
Grundlagen
Einwirkungen
der
auf
CEN
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung
Central Secretariat: rue de Stassart 36, B-1050 Brussels
© CEN 1997 Copyright reserved to all CEN members
Ref.No ENV 1991-2-5:1997
Page 2
ENV 1991-1-5:1997
Contents
Page
Foreword
Objectives of the Eurocodes
Background to the Eurocode Programme
Eurocode Programme
National Application Documents (NAD's)
Matters Specific to this Prestandard
3
4
4
4
5
5
1
1.1
1.1.1
1.1.2
1.1.3
1.2
1.3
1.4
1.5
General
Scope
Scope of ENV 1991-Eurocode 1
Scope of ENV 1991-2-5 Thermal Actions
Further Parts of ENV 1991
Normative references
Distinction between principles and application rules
Definitions
Symbols
7
7
7
7
8
8
9
9
10
2
Classification of actions
13
3
Design situations
14
4
Representation of actions
15
5
5.1
5.1.1
5.1.2
5.1.3
Temperature changes in buildings
General
Building structures
Cladding elements
Determination of temperature profiles
17
17
17
18
18
6
6.1
6.1.1
6.1.2
6.1.3
6.1.4
6.1.5
6.1.6
Temperature changes in bridges
Bridge decks
Bridge deck groupings
Treatment of thermal actions
Uniform temperature component - characteristic values
Linear temperature component - characteristic values
Co-existence of uniform and linear temperature components
Differences in effective temperature between different structural
elements
6.2
Bridge piers
6.2.1 Treatment of thermal actions
6.2.2 Temperature differences - characteristic value
19
19
19
19
19
22
23
24
24
24
24
Page 3
ENV 1991-2-5:1997
7
7.1
7.2
7.2.1
7.2.2
7.2.3
7.2.4
7.3
7.4
7.5
7.6
Temperature changes in industrial chimneys and pipelines
General
Temperature components - characteristic values
Shade air temperature
Solar radiation
Flue gas temperature
Effective element temperature
Thermal actions to be considered
Determination of temperature components
Characteristic values of temperature components (indicative values)
Combination of actions
25
25
25
25
25
25
26
26
26
26
27
Annex A Isotherms of national minimum and maximum shade air
temperatures (Informative)
29
Annex B Models for the assessment of non-linear thermal actions in
bridges (Normative)
48
Annex C Determination of temperature effects in bridge decks
(Informative)
52
Annex D Coefficients of linear expansion (Informative)
58
Page 4
ENV 1991-2-5:1997
Foreword
Objectives of the Eurocodes
(1) The "Structural Eurocodes" comprise a group of standard for the structural and
geotechnical design of buildings and civil engineering works.
(2) They cover execution and control only to the extent that is necessary to indicate the quality
of the construction products, and the standard of the workmanship, needed to comply with the
assumptions of the design rules.
(3) Until the necessary set of harmonized technical specification for products and for methods
of testing their performance are available, some of the Structural Eurocodes cover some of
these aspects in informative Annexes.
Background to the Eurocode Programme
(4) The Commission of the European Communities (CEC) initiated the work of establishing a
set of harmonized technical rules for the design of building and civil engineering works which
would initially serve as an alternative to the different rules in force in the various Member
States and would ultimately replace them. These technical rules became known as the
"Structural Eurocodes".
(5) In 1990, after consulting their respective Member States, the CEC transferred the work of
further development, issue and updating of the Structural Eurocodes to CEN, and the EFTA
Secretariat agreed to support the CEN work.
(6) CEN Technical Committee CEN/TC 250 is responsible for all Structural Eurocodes.
Eurocode Programme
(7) Work is in hand on the following Structural Eurocodes, each generally consisting of a
number of parts:
EN 1991
Eurocode 1
Basis of design and actions on structures
EN 1992
Eurocode 2
Design of concrete structures
EN 1993
Eurocode 3
Design of steel structures
EN 1994
Eurocode 4
Design of composite steel and concrete structures
EN 1995
Eurocode 5
Design of timber structures
EN 1996
Eurocode 6
Design of masonry structures
EN 1997
Eurocode 7
Geotechnical design
EN 1998
Eurocode 8
Design of structures for earthquake resistance
EN 1999
Eurocode 9
Design of aluminium alloy structures
(8) Separate sub-committees have been formed by CEN/TC250 for the various Eurocodes
listed above.
Page 5
ENV 1991-2-5:1997
(9) This part of Eurocode 1 is being published by CEN as a European Prestandard (ENV) with
an initial life of three years.
(10) This Prestandard is intended for experimental application and for the submission of
comments.
(11) After approximately two years CEN members will be invited to submit formal comments
to be taken into account in determining future actions.
(12) Meanwhile feedback and comments on this Prestandard should be sent to the Secretariat
of CEN/TC250/SC1 at the following address:
SIS/BST
Box 490 44
S-100 28 Stockholm
SWEDEN
or to your national standards organisation.
National Application Documents (NADs)
(13) In view of the responsibilities of authorities in member countries for safety, health and
other matters covered by the essential requirements of the Construction Products Directive
(CPD), certain safety elements in this ENV have been assigned indicative values which are
or [ ] (“boxed values”). The authorities in each member country are
identified by
expected to review the “boxed values” and may substitute alternative definitive values for
these safety elements for use in national application.
(14) Some of the supporting European or International standards may not be available by the
time this Prestandard is issued. It is therefore anticipated that a National Application
Document (NAD) giving any substitute definitive values for safety elements, referencing
compatible supporting standards and providing guidance on the national application of this
Prestandard, will be issued by each member country or its Standards Organisation.
(15) It is intended that this Prestandard is used in conjunction with the NAD valid in the
country where the building or civil engineering works is located.
Matters Specific to this Prestandard
(16) The scope of Eurocode 1 is defined in 1.1.1 and the scope of this Part of Eurocode 1 is
defined in 1.1.2. Additional parts of Eurocode 1 which are planned are indicated in 1.1.3.
(17) This Part is complemented by a number of annexes, some normative and some
informative. The normative annexes have the same status as the sections to which they relate.
(18) The characteristic value of isotherms of National minimum and maximum shade air
temperatures shall be provided in the form of maps or otherwise (see Annex A) by the
competent authority. The value provided for characteristic loads shall conform with the
definitions given in ENV 1991-1 Clause 4.2.
Page 6
ENV 1991-2-5:1997
(19) Allowance shall be made in the NAD for local effects which are unlikely to have been
considered in the statistical analysis for national loads.
(20) Where there is doubt about the validity of the recommended minimum
and maximum shade air temperatures, the procedure to consult the
competent
authority
should
be
given
in
the
NAD.
Page 7
ENV 1991-2-5:1997
Section 1
General
1.1
Scope
1.1.1
Scope of ENV 1991 – Eurocode 1
(1)P ENV 1991 provides general principles and actions for the structural design of buildings
and civil engineering works including some geotechnical aspects and shall be used in
conjunction with ENV 1992-1999.
(2) It may also be used as a basis for the design of structures not covered in ENV 1992-1999
and where other materials or other structural design actions are involved.
(3) ENV 1991 also covers structural design during execution and structural design for
temporary structures. It relates to all circumstances in which a structure is required to give
adequate performance.
(4) ENV 1991 is not directly intended for the structural appraisal of existing construction, in
developing the design of repairs and alterations or, for assessing changes of use.
(5) ENV 1991 does not completely cover special design situations which require unusual
reliability considerations such as nuclear structures for which specific design procedures
should be used.
1.1.2
Scope of ENV 1991-2-5 Thermal Actions
(1)P This Part gives rules and methods of calculating thermal actions on buildings, bridges
and other structures including their structural components. Principles needed for cladding and
other appendages of the buildings are also provided.
(2) This Part of the Eurocode on Actions on Structures describes the changes in the
temperature of structural elements. Characteristic values of thermal actions are presented for
use in the design of structures which are exposed to daily and seasonal climatic changes.
(3) Structures in which thermal actions are mainly a function of their use (e.g. chimneys,
cooling towers, silos, tanks, warm and cold storage facilities, hot and cold services) are treated
in section 7.
(4) The following subjects are dealt with:
Section 1 - General
Section 2 - Classification of actions
Section 3 - Design situations
Section 4 - Representation of actions
Section 5 - Temperature changes in buildings
Section 6 - Temperature changes in bridges
Section 7 - Temperature differences in industrial chimneys and pipelines
Page 8
ENV 1991-2-5:1997
1.1.3 Further Parts of ENV 1991
(1) Further Parts of ENV 1991 which, at present, are being prepared or are planned are given
in 1.2.
1.2 Normative references
This European Prestandard incorporates by dated or undated reference, provisions from other
standards. These normative references are cited at the appropriate places in the text and
publications listed hereafter.
ISO 3898 1987
Basis of design for structures
Notations. General symbols
NOTE: The following European Prestandards which are published or in preparation are
cited at the appropriate places in the text and publications listed hereafter.
ENV 1991-1
Eurocode 1: Basis of design and actions on structures
Part 1 : Basis of design
ENV 1991-2-1
Eurocode 1: Basis of design and actions on structures
Part 2.1 Densities, self-weight, imposed loads
ENV 1991-2-2
Eurocode 1: Basis of design and actions on structures
Part 2.2 Actions on structures exposed to fire
ENV 1991-2-3
Eurocode 1: Basis of design and actions on structures
Part 2.3: Snow loads
ENV 1991-2-4
Eurocode 1: Basis of design and actions on structures
Part 2.4: Wind actions
ENV 1991-2-6
Eurocode 1: Basis of design and actions on structures
Part 2.6: Actions during execution
ENV 1991-2-7
Eurocode 1: Basis of design and actions on structures
Part 2.7: Accidental actions due to impact and explosions
ENV 1991-3
Eurocode 1: Basis of design and actions on structures
Part 3: Traffic loads on bridges
ENV 1991-4
Eurocode 1: Basis of design and actions on structures
Part 4: Actions in silos and tanks
ENV 1991-5
Eurocode 1: Basis of design and actions on structures
Part 5: Actions induced by cranes and machinery
ENV 1992
Eurocode 2: Design of concrete structures
ENV 1993
Eurocode 3: Design of steel structures
ENV 1994
Eurocode 4: Design of composite steel and concrete structures
ENV 1995
Eurocode 5: Design of timber structures
ENV 1996
Eurocode 6: Design of masonry structures
ENV 1997
Eurocode 7: Geotechnical design
Page 9
ENV 1991-2-5:1997
1.3
ENV 1998
Eurocode 8: Earthquake resistant design of structures
ENV 1999
Eurocode 9: Design of aluminium alloy structures
Distinction between principles and application rules
(1) Depending on the character of the individual clauses, distinction is made in this Part 2-5 of
ENV 1991 between principles and application rules.
(2) The principles comprise:
– general statements and definitions for which there is no alternative, as well as;
– requirements and analytical models for which no alternative is permitted unless
specifically stated.
(3) The principles are identified by the letter P following the paragraph number.
(4) The application rules are generally recognised rules which follow the principles and satisfy
their requirements.
(5) It is permissible to use alternative rules different from the application rules given in this
Eurocode, provided it is shown that the alternative rules accord with the relevant principles
and have at least the same reliability.
(6) In this Part of ENV 1991 the application rules are identified by a number in brackets e.g.
as this clause.
Page 10
ENV 1991-2-5:1997
1.4
Definitions
For the purposes of this prestandard, a basic list of definitions is provided in ENV 1991-1, and
the additional definitions given below are specific to this Part.
1.4.1 Thermal actions: Thermal actions on a structure or a structural element are the ranges
of temperature fields within a specified time interval.
1.4.2 Shade air temperature: The shade air temperature is the temperature measured by
thermometers placed in a white painted louvred wooden box known as a “Stevenson screen”.
The object of the screen is to shield the thermometers from (i) radiation by day from the sun,
the ground or neighbouring objects, (ii) loss of heat by radiation at night, and (iii)
precipitation, while at the same time allowing free passage of air. This is achieved by the use
of louvres in the sides and door, a double roof with an air space and a floor consisting of three
partially overlapping boards separated by an air space. The screen in mounted on a stand so
that the thermometer bulbs are about 1,20 m above the ground, which can be taken as level,
covered with short grass and well away from trees, buildings, walls or other obstructions. The
dry bulb thermometer gives the air temperature at the time of observation and the maximum
and minimum thermometers are read once or more daily, according to the type of station, and
set immediately after they are read.
1.4.3 Maximum shade air temperature Tmax: annual value of maximum shade air
temperature with return period 50 years, based on the maximum hourly values recorded.
1.4.4 Minimum shade air temperature Tmin: annual value of minimum shade air
temperature with return period 50 years, based on the minimum hourly values recorded.
1.5 Symbols
(1) For the purposes of this Part of Eurocode 1, the following symbols apply.
NOTE: The notation used is based on ISO 3898:1987
(2) A basic list of notations is provided in ENV 1991-1, and the additional notations below are
specific to this Part.
Latin upper case letters
Tmax
annual value of maximum shade air temperature with return period 50 years,
based on the maximum hourly values recorded
Tmin
annual value of minimum shade air temperature with return period 50 years, based
on the minimum hourly values recorded
R
return period of maximum (minimum) shade air temperature [years]
Tmax,R
annual value of maximum shade air temperature with return period R
Tmin,R
annual value of minimum shade air temperature with return period R
Te.max
maximum effective bridge temperature
Te.min
minimum effective bridge temperature
Page 11
ENV 1991-2-5:1997
T0
datum effective structural element temperature when is restrained
T1,T2,
T3,T4
values of positive (negative) temperature difference profile
∆TK
characteristic value of thermal action
∆T1'
infrequent value of thermal action
∆T1
frequent value of thermal action
∆T2
quasi-permanent value of thermal action
∆TN,pos maximum range of positive effective bridge temperature
∆TN,neg maximum range of negative effective bridge temperature
∆TN
overall range of effective bridge temperature
∆TM,pos positive linear temperature differences
∆TM,neg negative linear temperature differences
∆TE
non-linear part of the temperature differences
o
degree used for temperature values e.g. shade air temperature, datum temperature,
effective bridge temperature, temperature differences
A
area of the cross-section
E
Young’s modulus of elasticity
J
moment of inertia
B
width of the cross-section
H
height of the cross-section
C
Latin lower case letters
d
wall thickness of the chimney or pipeline
u, c
location and scale parameters of annual maximum (minimum) shade air
temperature distribution
k1, k2
coefficients for calculation of maximum (minimum) shade air
k3, k4
temperature with return period other than 50 years
ksur
surfacing factor for linear temperature differences
Greek lower case letters
αT
coefficient of linear expansion (1/°C)
ωN
reduction factor of uniform temperature component for combination with linear
temperature differences
ωM
reduction factor of linear temperature differences for combination with uniform
temperature component
Page 12
ENV 1991-2-5:1997
ψ0
Coefficient for combination value of thermal action
ψ1'
Coefficient for infrequent value of thermal action
ψ1
Coefficient for frequent value of thermal action
ψ2
Coefficient for quasi-permanent value of thermal action
Page 13
ENV 1991-2-5:1997
Section 2
Classification of actions
(1)P Thermal actions are classified as variable, free actions, see ENV 1991-1.
(2)P Thermal actions are indirect actions, see ENV 1991-1.
(3) Characteristic values of thermal actions as given in this Part are 50
years
return
values,
unless
stated
otherwise.
Page 14
ENV 1991-2-5:1997
Section 3
Design situations
(1)P The relevant thermal actions shall be determined for each design situation identified in
accordance with ENV 1991-1 and ENV 1991-3.
(2)P The temperature distribution within a cross-section of any element leads to deformation
of the element. When the deformation is restrained, stresses occur in the element. These
stresses shall be considered for both persistent and transient design situations (e.g. during
execution or repair) according to ENV 1991-1.
(3)P The elements of the loadbearing structure shall be checked to ensure that thermal
movement will not cause overstressing of the structure, either by the provision of expansion
joints or by including the effects in the design.
(4) In special cases accidental design situations should be considered, see section 7.1.
Page 15
ENV 1991-2-5:1997
Section 4
Representation of actions
(1)P Daily and seasonal changes in shade air temperature, solar radiation, re-radiation, etc.,
will result in variations of the temperature distribution within individual elements of a
structure.
(2)P The magnitude of the thermal effects will be dependent on local climatic conditions,
together with the orientation of the structure, its overall mass, finishes (e.g. cladding in
buildings), and in the case of building structures, heating and ventilation regimes and thermal
insulation.
(3) The temperature distribution within an individual structural element may be split into the
following four essential constituent components, as illustrated in figure 4.1:
a)
A uniform temperature component, ∆TN;
b)
A linearly varying temperature component about the z-z axis, ∆TMZ;
c)
A linearly varying temperature component about the y-y axis, ∆TMY;
d)
A non-linear temperature distribution, ∆TE. This results in a system of selfequilibrated stresses which produce no net load effect on the element.
y
y
z
z
x
Center of
gravity
(a)
(b)
∆ΤMY(c)
(d)
Figure 4.1: Constituent components of a temperature profile
(4)P The strains and therefore any resulting stresses, are dependent on the geometry and
boundary conditions of the element being considered and on the physical properties of the
material used. When materials with different coefficients of linear expansion are used
compositely see annex C5.
Page 16
ENV 1991-2-5:1997
Section 5
5.1
Temperature changes in buildings
General
(1)P This Section deals with the effects of thermal actions on building structures and cladding
where the temperature within the envelope normally varies by less than 20oC during normal
use.
(2)P This section only deals with thermal actions arising from climatic effects due to the
variation of shade air temperature and solar radiation. The possible effects of shading by
adjacent buildings should be taken account in the design. Thermal actions arising from
internal unfavourable heating, effects of plant or industrial processes shall be covered in the
project specification.
(3) The allowances required in assessing the behaviour of the structure and its cladding are
dependent on the type of structure, the cladding employed and the expected internal and
external temperature history. Accordingly specific rules cannot be provided.
(4) The following rules are a guide to the matters which should be considered in the design;
appropriate detailed assessments for each structure should be considered in the design.
(5) To define the effects of thermal actions on buildings, three definitions are required:
– building envelope; the part of structure providing either or both the weather resistant
membrane or the structural skin to the building;
– cladding: the part of the building not carrying load other than self weight or wind which
provides a weatherproof membrane;
– load bearing structure: those elements which carry the actions applied to the building;
permanent finishes and internal structural walls are included.
(6)P The effects of thermal actions shall be considered where there is a possibility of the
ultimate or serviceability limit states being exceeded due to thermal movement. In particular
the differential movement between components formed from differing materials shall be taken
into account in the design.
NOTE: The provision of movement joints may also be influenced by moisture and other
environmental factors.
5.1.1
Building structures
(1)P The elements of the load bearing structure shall be checked to ensure that thermal
movement will not cause exceedance of limit states of the structure, either by the provision of
expansion joints or by including the thermal effects in the design. Allowance shall be made
for any differential movement between the structure and the cladding.
(2)P Structural elements not protected from the external environment by cladding shall be
checked to ensure that there is no increase in risk due to higher thermal variations. Where
critical (e.g. slabs of environmental protection structures) the effects of solar radiation and
uneven temperature distribution shall be considered.
Page 17
ENV 1991-2-5:1997
5.1.2
Cladding elements
(1)P The effects of temperature variations shall be considered on cladding elements and the
effective length between movement joints shall be determined on the performance of the
materials employed in the construction. Where different forms of cladding are used on the
structure then account shall be taken of the variations, such as expansion and rate of heat
change, between the materials.
(2)P The cladding materials shall be fixed to the structure in such a manner as to allow for all
differential movement between the various components.
(3)P The differential movement due to the variation of the shade air temperature and that due
to solar radiation shall be considered in the design of the cladding and its fixings.
5.1.3
Determination of temperature profiles
(1)P The temperature profiles shall be determined on a national basis taking into account the
exposure to daily variation of solar radiation and the daily range of the shade air temperature.
(2) If specific information on how the effective building temperatures can be correlated with
the shade air temperature and solar radiation is available in order to provide reliable effective
building temperatures for design, such information should be used to provide characteristic
values.
(3) For buildings where calculation is needed, a uniform temperature in structural elements
may be assumed in most cases.
NOTE: Information of shade air temperatures is given in annex A3. The temperatures
are applicable to both bridges and buldings.
Page 18
ENV 1991-2-5:1997
Section 6
Temperature changes in bridges
6.1
Bridge decks
6.1.1
Bridge deck groupings
(1)P A bridge deck shall be considered as one of the following three superstructure groups:
Group 1
Steel deck on steel box, truss or plate girders;
Group 2
Concrete deck on steel box, truss or plate girders;
Group 3
Concrete slab or concrete deck on concrete beams or box girders.
NOTE: See also annex B.
(2) In the absence of codified values for effective temperatures and temperature differences
for other types of bridges, appropriate values should be derived from first principles, specialist
data or test results.
6.1.2
Consideration of thermal actions
(1) The following rules apply to bridge decks that are exposed to daily and seasonal climatic
effects. Bridges not so exposed may not need to be considered for thermal actions.
(2) For bridges, all representative values of thermal actions should be assessed by the uniform
temperature component (see 6.1.3) and the linear temperature component (see 6.1.4).
(3) In cases where non-linear distributions need to be considered in detail – That is in cases
where sufficient detailing provisions can not be provided (e.g. composite structure) –
appropriate temperature differences should be applied. Values are given in annex B.
6.1.3 Uniform temperature component - characteristic values
6.1.3.1 General
(1) The uniform temperature component depends on the minimum and maximum effective
bridge temperature which a bridge will achieve over a prescribed period of time. This results
in a range of uniform temperature changes which, in an unrestrained structure would result in
a change in element length.
(2) The following effects can however be produced within a structure due to:
– Restraint of associated expansion or contraction due to the type of construction (e.g.
portal frame, arch, elastomeric bearings);
– Friction at roller or sliding bearings;
– Non-linear geometric effects (2nd order effects);
– For railway bridges the interaction effects between the track and the bridge due to the
variation of the temperature of the deck and of the rails induce supplementary horizontal
forces in the bearings (and supplementary forces in the rails). For more information, see
ENV 1991-3.
Page 19
ENV 1991-2-5:1997
(3)P Minimum and maximum effective bridge temperatures shall be derived from isotherms
of minimum and maximum shade air temperatures (see 6.1.3.2 and 6.1.3.3).
Te.max
Te.min
70
Group 1
60
Group 2
maximum
50
Group 3
40
30
20
Group 3
10
Group 2
0
Group 1
-10
-20
-30
-40
minimum
-40
-30
-20
-10
0
10
20
30
40
50
Tmax
Tmin
NOTE: For steel truss and plate girders the maximum values given for group 1 may be
reduced by 3oC.
Figure 6.1: Correlation between minimum / maximum shade air temperature
(Tmin / Tmax) and minimum / maximum effective bridge temperature (Te.min / Te.max)
(4) The effective bridge temperature may be calculated from the shade air temperature using
Figure 6.1. The values in Figure 6.1 have been based on daily temperature ranges of 10oC.
Such a range may be considered appropriate for most Member States. If specific data are
available to justify a different temperature range the values obtained from Figure 6.1 should
be adjusted.
6.1.3.2 Shade air temperature
(1)P Characteristic values of minimum and maximum shade air temperatures shall be obtained
at the site location with reference to the maps of isotherms shown for each Member State in
annex A. These shade air temperatures are appropriate to mean sea level in open country with
a return period of 50 years. Adjustments for other return periods, height above sea level and
local conditions e.g. frost pockets are included in annex A.
Page 20
ENV 1991-2-5:1997
(2) For circumstances where a 50 year return period is deemed inappropriate, the minimum
shade air temperatures and the maximum shade air temperatures should be modified in
accordance with annex A.
6.1.3.3 Range of effective bridge temperatures
(1)P The characteristic values of minimum and maximum effective bridge temperatures for
restraining forces shall be derived from the minimum (Tmin) and maximum (Tmax) shade air
temperatures by reference to Figure 6.1. The likely effective bridge temperature To at the time
that the structure is effectively restrained shall be taken from annex A as the datum in
calculating contraction down to the minimum effective bridge temperature and expansion up
to the maximum effective bridge temperature.
(2) Thus the characteristic value of maximum range of negative effective bridge temperature,
∆TN,neg should be taken as
∆TN,neg = Te.min - To
(6.1)
and the characteristic value of maximum range of positive effective bridge temperature,
∆TN,pos should be taken as
∆TN,pos = Te .max - To
(6.2)
NOTE: The overall range of effective bridge temperature ∆TN = Te.max - Te.min
(3)P For the design of range of movements (e.g. in the design of bearings and expansion
joints), the maximum range of positive effective bridge temperature shall be taken as
(∆TN,pos + 20 )oC, and the maximum range of negative effective bridge temperature shall be
taken as (∆TN,neg - 20 )oC, if no other provision is required. If the temperature at which the
bearings and expansion joints are set is known, then the 20 oC figure in the ranges above
can be reduced to 10 oC.
6.1.4
Linear temperature component - characteristic values
6.1.4.1 Vertical component
(1) Over a prescribed period heating and cooling of a bridge deck's upper surface will result in
a maximum positive (top surface warmer) and a maximum negative (bottom surface warmer)
temperature variation. When materials with different coefficients of linear expansion are used
compositely, see annex C.
(2) This will produce effects within a structure due to:
– Restraint of free curvature due to the form of the structure (e.g. portal frame, continuous
beams etc.);
– Friction at rotational bearings;
– Non-linear geometric effects (2nd order effects).
Page 21
ENV 1991-2-5:1997
(3) These effects shall be represented by the equivalent positive and negative linear
temperature differences as given in Table 6.1.
Table 6.1:
Groups of
Superstructure
(see Annex B)
Group 1:
Steel deck on steel box,
truss or plate girders
Group 2:
Concrete deck on steel
box, truss or plate
girders
Group 3:
Concrete deck on
– concrete box girder
– concrete T-girder
– concrete slab
Characteristic values of linear temperature differences for
different groups of bridge superstructures
road bridges
Positive
Negative
Temperature Temperature
Difference
Difference
railway bridges
Positive
Negative
Temperature
Temperature
Difference
Difference
∆TM,pos (oC)
∆TM,neg (oC)
∆TM,pos (oC)
∆TM,neg (oC)
[18]
[-13]
[18]
[-13]
[15]
[-18]
[15]
[-18]
[10]
[15]
[15]
[-5]
[-8]
[-8]
[10]
[15]
[15]
[-5]
[-8]
[-8]
NOTE: Table based on upper bound of linearly varying temperature component for
representative sample of bridge geometries.
(4) For major bridges (e.g. spans greater than 100 m or where it is considered appropriate)
a numerical simulation of the temperature differences considering the method described in
annex C may be developed.
(5) The temperature differences given in Table 6.1 should be applied between the top and the
bottom of superstructure.
(6) The values of temperature differences given in Table 6.1 are based on a depth of surfacing
of 50 mm for road and railway bridges. For other depths of surfacing these values should be
multiplied by factor ksur as given in Table 6.2.
Page 22
ENV 1991-2-5:1997
Table 6.2:
Factors ksur to account for different surfacing thickness
Road and railway bridges
Surface
concrete
Thickness
top warmer
than bottom
(mm)
steel
top warmer
than bottom
ksur
bottom
warmer
than
top
ksur
0
1,5 1)
50
composite
top warmer
than bottom
ksur
bottom
warmer
than
top
ksur
ksur
bottom
warmer
than
top
ksur
1,0
1,6 1)
0,6
1,1
0,9
1,0
1,0
1,0
1,0
1,0
1,0
100
0,7
1,0
0,7
1,2
1,0
1,0
150
0,5
1,0
0,7
1,2
1,0
1,0
ballast
(60 cm)
0,6
1,0
0,6
1,4
0,8
1,2
NOTE 1: Values represent upper bounds.
6.1.4.2 Horizontal component
(1) The linear temperature distribution should in general only need to be considered in the
vertical direction. In particular cases however, a horizontal temperature gradient may need to
be considered. In such cases if no other information is available and no indications for higher
values exist 5 oC may be taken as the temperature difference to be used.
6.1.5 Simultaneity of uniform and linear temperature components
(1) If it is necessary to take into account both the temperature difference ∆TM and the uniform
temperature component ∆TN assuming simultaneity (e.g. in case of frame structures) the
following expression may be used:
∆TM + ω N ∆TN
(6.3)
ω M ∆TM + ∆TN
(6.4)
or
where the most adverse effect should be chosen and where:
ωN =
0,35 ;
Page 23
ENV 1991-2-5:1997
ωM =
6.1.6
0,75 .
Differences in effective temperature between different structural elements
(1) In certain structures, differences in effective temperature between element types may cause
adverse load effects. In addition to the effects resulting from a uniform effective temperature
in all elements, the effects resulting from a difference in effective temperature of 15 oC
between main structural elements (e.g. tie and arch, suspension / stay cables and deck girder)
should be considered.
6.2
Bridge Piers
6.2.1
Consideration of thermal actions
(1)P Linear temperature differences between the outer faces of bridge piers, hollow or solid,
shall be considered in design.
(2) Overall temperature effects of piers should be considered, when these can lead to
restraining forces or movements in the surrounding structures.
6.2.2
Temperature differences - characteristic values
(1) Characteristic values of the linear temperature differences between opposite outer faces
should be taken as 5 oC for concrete piers, hollow or solid, in the absence of detailed
information and in the absence of indication of higher values.
(2) Characteristic values of the linear temperature differences between the inner and outer
faces of the wall should be taken as 15 oC.
(3) When considering linear temperature differences for steel columns specialist advice should
be obtained.
Page 24
ENV 1991-2-5:1997
Section 7
7.1
Temperature changes in industrial chimneys and pipelines
General
(1)P This section only provides quantifiable values for thermal actions from climatic effects,
due to the variation of shade air temperature and solar radiation.
(2)P Values of operating process temperature shall be obtained from the project specification.
(3)P Structures which are in contact with heated gas flow or heated material (e.g. chimneys,
pipelines and silos), shall be designed where relevant for the following thermal actions:
– temperature distribution for normal process conditions;
– accidental temperature distribution from failures in operation.
7.2
Temperature components – characteristic values
7.2.1 Shade air temperature
(1)P Characteristic values of minimum and maximum shade air temperature shall be obtained
at the site location with reference to the maps of isotherms shown for each Member State in
annex A. These values of shade air temperature are generally appropriate to mean sea level
and local conditions e.g. frost pockets are included in annex A.
(2) For circumstances where a 50 year return period is deemed inappropriate, as for transient
situations, the values of minimum (maximum) shade air temperature should be modified in
accordance with annex A.
7.2.2
Solar radiation
(1)P Chimneys and pipelines which are exposed to daily and seasonal climatic effects will be
subjected to solar radiation which will affect the appropriate temperature to be used in design.
Characteristic values of solar radiation shall be provided either by National Meteorological
Stations or in the project specification.
7.2.3
Flue gas temperature
(1)P Characteristic values (50 year return period) of maximum and minimum flue gas
temperature shall be obtained from the project specification.
7.2.4
Effective element temperature
(1) The derivation of characteristic values of effective element temperature will depend on the
material configuration, orientation and location of the element and will be a function of the
maximum and minimum shade air temperature and the solar radiation. Rules cannot be
provided in this Code and recourse will need to be made either to specialist advice or to the
use of the indicative values given in 7.5.
7.3
Thermal actions to be considered
Page 25
ENV 1991-2-5:1997
(1)P Both the uniform temperature component of the temperature distribution (see Figure 4.1
(a)) and the linearly varying temperature component (see Figure 4.1 (b)) shall be considered.
(2)P Solar radiation causing a stepped temperature distribution round the structure’s
circumference shall be considered.
(3)P Uniform and linearly varying temperature components due to process temperature shall
be considered.
7.4
Determination of temperature components
(1)P The uniform and linearly varying temperature profiles due to climatic effects shall be
determined on a national basis taking into account the exposure to the daily variation of the
solar radiation and the daily range of the shade air temperature.
(2) If specific information on how the effective element temperature can be correlated with the
solar radiation and shade air temperature is available in order to provide characteristic values
of effective element temperature for design, such information should be used to provide
design values.
(3)P Characteristic values of the uniform temperature component from liquids or flue gases
shall be taken from the project specification.
(4)P Linearly varying temperature component from liquids or the gases shall be taken as
arising from the difference between the minimum (or maximum) shade air temperature and
the characteristic value of the liquid or flue gas temperature, taking into account insulation
effects.
7.5
Characteristic values of temperature components (indicative values)
(1) In the absence of any specific information on characteristic values of the element
temperature the following indicative values may be used.
NOTE: These values are based on current experience and they should be checked
against any available data to ensure that they are likely to be upper bound values, for the
location and type of element under consideration.
(2) Characteristic values of the maximum and minimum uniform temperature component
should be taken as those of the maximum and minimum shade air temperature (see 7.2.1).
(3) For concrete chimneys and concrete pipelines characteristic values of the linear
temperature differences between the inner and outer faces of the wall should be taken as
15 oC.
(4) For concrete chimneys and concrete pipelines a stepped temperature distribution round the
structure’s circumference (causing both overall and local thermal effects) should be
considered on the basis that one 90o quadrant of its curcumference has a mean temperature
15 oC higher than that of the remainder of the circumference.
Page 26
ENV 1991-2-5:1997
(5) When considering steel chimneys and steel pipelines, the linear temperature difference and
stepped temperature distribution round the structure’s circumstance should be set down in the
project specification or specialist advice should be obtained.
7.6
Simultaneity of actions
(1) When considering thermal actions due to climatic effects only, the following components
should take account of simultaneity:
a) uniform temperature component (see 7.5 (2) and Figure 7.1 (a));
b) the stepped distribution (see 7.5 (4) and Figure 7.1 (b));
c) linear temperature differences between the inner and the outer faces of the wall (see
7.5 (3) and Figure 7.1 (c)).
(2) When considering a combination of thermal actions due to climatic effects with those due
to process effects (liquids or flue gases) the following components should take into account
simultaneity:
– uniform temperature component due to flue gas temperature (see 7.4 (3));
– linear temperature differences (see 7.4 (4));
– the stepped distribution (see 7.5 (4)).
(3) Where stepped temperature distribution is considered, it should be combined with wind
effects (including vortex shedding and ovalisation) at the appropriate wind speed to cause
maximum response from these effects.
Page 27
ENV 1991-2-5:1997
(a) Uniform temperature
component
∆TN
90o
(b) Stepped temperature
distribution round the
circumference
15oC
outer face
warmer
∆TM
(c) Linear temperature
differences between
the inner and the outer
faces of the wall
inner face
warmer
∆TM
Figure 7.1:
Relevant temperature components for industrial chimneys and pipelines
Page 28
ENV 1991-2-5:1997
Annex A
(Informative)
Isotherms of national minimum and maximum shade air temperatures
A.1
General
(1) This annex contains maps of isotherms of both annual minimum and annual maximum
shade air temperatures for Member States.
(2) The maps represent 50 year return period values. These values may need to be adjusted for
height above see level according to A.3. However in the absence of this information the
values of shade air temperature should be adjusted for height above sea level by subtracting
0,5 oC per 100 m height for minimum shade air temperature and 1,0 oC per 100 m
height for maximum shade air temperature.
(3) There are locations where the minimum values diverge from the values given as, for
example, frost pockets and sheltered low lying areas where the minimum may be substantially
lower, or in large conurbations and coastal sites, where the minimum may be higher, than that
indicated in the relevant figures. These divergences should be taken into consideration using
local meteorological data.
(4) The datum temperature T0 should be taken from the information provided by each Member
State in this annex. In the absence of specific values, T0 should be taken as 10 oC.
A.2
Maximum and minimum shade air temperature values for return periods other
than 50 years
(1) If Tmax,R (Tmin,R) is value of maximum (minimum) shade air temperature with mean return
period R other than 50 years the ratio Tmax,R/Tmax (Tmin,R/Tmin) may be determined from Figure
A2.1, based on UK data.
(2) In general Tmax,R (Tmin,R) may be found using the following expressions based on a type I
extreme value distribution:
– for maximum:
Tmax,R = Tmax {k1 - k2 ln[-ln(1-1/R) ] }
(A.1)
– for minimum:
Tmin,R = Tmin {k3 + k4 ln[-ln(1-1/R) ] }
(A.2)
where:
Tmax (Tmin) is the value of maximum (minimum) shade air temperature with return period
50 years;
k1 = (uc) / { (uc) + 3,902 }
(A.3)
k2 = 1 / { (uc) + 3,902 }
(A.4)
where:
u, c
are location and scale parameters of annual maximum shade air temperature
distribution;
Page 29
ENV 1991-2-5:1997
k3 = (uc) / { (uc) - 3,902 }
k4 = 1 / { (uc) - 3,902 }
(A.5)
(A.6)
where:
u, c
are location and scale parameters of annual minimum shade air temperature
distribution.
Coefficients k1, k2, k3 and k4 should be based on values of u and c given by national
responsible authorities. In the absence of specific data the following values based on U.K.
data may be used:
k1 = 0,781;
k2 = 0,056;
k3 = 0,393;
k4 = - 0,156.
The ratios Tmax,R/Tmax and Tmin,R/Tmin respectively may then be taken from Figure A.1.
R
maximum
minimum
200
150
100
70
50
20
10
5
Ratios
2
0.4
0.5
Figure A.1:
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
Ratios Tmax,R / Tmax and Tmin,R / Tmin
Page 30
ENV 1991-2-5:1997
A.3
List of national maps of isotherms of minimum and maximum shade air
temperatures
A.3.1 Map of Austria
A.3.2 Map of Belgium
A.3.3 Map of Czech Republic
A.3.4 Map of Denmark
A.3.5 Map of Finland
A.3.6 Map of France
A.3.7 Map of Germany
A.3.8 Map of Greece
A.3.9 Map of Iceland
A.3.10 Map of Ireland
A.3.11 Map of Italy
A.3.12 Map of Luxembourg
A.3.13 Map of Netherlands
A.3.14 Map of Norway
A.3.15 Map of Portugal
A.3.16 Map of Slovakia
A.3.17 Map of Spain
A.3.18 Map of Sweden
A.3.19 Map of Switzerland
A.3.20 Map of United Kingdom
Page 31
ENV 1991-2-5:1997
A.3.2 Belgium
(1)
Isotherms
of
minimum
shade
air
temperature
in
o
C
Page 32
ENV 1991-2-5:1997
A.3.2 Belgium
(2)
Isotherms
of
maximum
shade
air
temperature
in
o
C
Page 33
ENV 1991-2-5:1997
A.3.3 Czech Republic
(1)
Isotherms
of
minimum
shade
air
temperature
in
o
C
Page 34
ENV 1991-2-5:1997
A.3.3 Czech Republic
(1)
Isotherms
of
maximum
shade
air
temperature
in
o
C
Page 35
ENV 1991-2-5:1997
A.3.5 Finland
(1)
Isotherms
of
minimum
shade
air
temperature
in
o
C
Page 36
ENV 1991-2-5:1997
A.3.5 Finland
(2)
Isotherms
of
maximum
shade
air
temperature
in
o
C
Page 37
ENV 1991-2-5:1997
A.3.7 Germany
(1) Isotherm of minimum shade air temperature
In general the minimum shade air temperature may be taken as -24 °C.
(2) Isotherm of maximum shade air temperature
In general the maximum shade air temperature may be taken as +37 °C.
Page 38
ENV 1991-2-5:1997
A.3.10 Ireland
(1) Isotherms of minimum shade air temperature in oC
k3 = 0,500
k4
=
-
0,130
Page 39
ENV 1991-2-5:1997
A.3.10 Ireland
(2) Isotherms of maximum shade air temperature in oC
k1 = 0,800
k2
=
0,052
Page 40
ENV 1991-2-5:1997
A.3.11 Italy (UNOFFICIAL MAP)
(1)
Isotherms
of
minimum
shade
air
temperature
in
o
C
Page 41
ENV 1991-2-5:1997
A.3.11 Italy (UNOFFICIAL MAP)
(2)
Isotherms
of
maximum
shade
air
temperature
in
o
C
Page 42
ENV 1991-2-5:1997
A.3.12 Luxemburg
(1) Isotherm of minimum shade air temperature
In general the minimum shade air temperature may be taken as -24 °C.
(2) Isotherm of maximum shade air temperature
In general the maximum shade air temperature may be taken as +37 °C.
Page 43
ENV 1991-2-5:1997
A.3.13 Netherlands
(1) Isotherm of minimum shade air temperature
In general the minimum shade air temperature may be taken as -22 °C.
For coastal provinces N -Holland, Z -Holland and Zeeland
the minimum shade air temperature may be taken as -17 °C.
(2) Isotherm of maximum shade air temperature
In general the maximum shade air temperature may be taken as +38 °C.
For coastal provinces N -Holland, Z -Holland and Zeeland
the maximum shade air temperature may be taken as +35 °C.
Page 44
ENV 1991-2-5:1997
A.3.16 Slovakia
(1) Isotherms of minimum shade air temperature in oC
Page 45
ENV 1991-2-5:1997
A.3.16 Slovakia
(2) Isotherms of maximum shade air temperature in oC
Page 46
ENV 1991-2-5:1997
A.3.17 Spain
(1) Isotherms of minimum shade air temperature in oC
Values have been determined using the following method:
– temperature data from 1961 to 1990;
– adjustments have been made using an extreme value distribution function. Maximum
likelihood;
– 50 years return period;
– 90 per cent confidence level;
– the map has been developed using Kriging linear method.
Page 47
ENV 1991-2-5:1997
A.3.17 Spain
(2) Isotherms of maximum shade air temperature in oC
Values have been determined using the following method:
– temperature data from 1961 to 1990;
– adjustments have been made using an extreme value distribution function. Maximum
likelihood;
– 50 years return period;
– 90 per cent confidence level;
– the map has been developed using Kriging linear method.
Page 48
ENV 1991-2-5:1997
A.3.18 Sweden
(1) Isotherms of minimum shade air temperature in oC
Data represent calculated 50 year observation period modal values of annual minimum
observed temperatures. Significant local deviations are to be expected in response to
topography and urban development.
Page 49
ENV 1991-2-5:1997
A.3.18 Sweden
(2) Isotherms of maximum shade air temperature in oC
Data represent calculated 50 year observation period modal values of annual maximum
observed temperatures. Significant local deviations are to be expected in response to
topography and urban development.
Page 50
ENV 1991-2-5:1997
A.3.19 Switzerland
(1) Isotherm of minimum shade air temperature
In general the minimum shade air temperature may be taken as:
North of the Alps
-28 °C;
South of the Alps
-20 °C.
(2) Isotherm of maximum shade air temperature
In general the maximum shade air temperature may be taken as:
North of the Alps
+38 °C;
South of the Alps
+36 °C.
Page 51
ENV 1991-2-5:1997
A.3.20 United Kingdom
(1)
Isotherms
of
minimum
shade
air
temperature
in
o
C
Page 52
ENV 1991-2-5:1997
A.3.20 United Kingdom
(2) Isotherms of maximum shade air temperature in oC
Page 53
ENV 1991-2-5:1997
Annex B
(Normative)
Models for the assessment of non-linear thermal actions in bridges
NOTE: The content of this annex may be brought into the main text at the EN stage in
the light of use by the Member States.
B.1
General
(1) This annex contains tables of positive and negative temperature difference profiles.
(2) Temperature difference profiles are presented for each of the three basic superstructure
groups shown in Figure B.1 for a variety of surfacing conditions.
(3) The temperature difference profiles presented are defined in the following tables and
figures.
B.2
Effect of surfacing depths
(1) The values of the temperature differences given in Figure B.1 may be used. The values are
valid for 40 mm surfacing depths for superstructure group 1 and 100 mm surfacing depths for
groups 2 and 3. For other depths of surfacing, the values given in tables B.1 to B.3 should be
used.
Table B.1:
Surfacing
thickness
mm
unsurfaced
20
40
T1
C
o
[30]
[27]
[24]
Values of T for superstructure group 1
Positive
temperature
difference profile
T2
T3
o
o
C
C
[16]
[15]
[14]
[6]
[9]
[8]
T4
C
Negative
temperature
difference profile
T1
o
C
[3]
[5]
[4]
[8]
[6]
[6]
o
Page 54
ENV 1991-2-5:1997
Figure B.1:
Temperature difference for different groups of superstructure
Page 55
ENV 1991-2-5:1997
Table B.2:
Values of T for superstructure group 2
Depth of slab (h)
Surface thickness
mm
Positive
temperature
difference
T1
o
C
Negative
temperature
difference
T1
o
C
m
0,2
unsurfaced
waterproofed
50
100
150
200
[16,5]
[23,0]
[18,0]
[13,0]
[10,5]
[8,5]
[5,9]
[5,9]
[4,4]
[3,5]
[2,3]
[1,6]
0,3
unsurfaced
waterproofed
50
100
150
200
[18,5]
[26,5]
[20,5]
[16,0]
[12,5]
[10,0]
[9,0]
[9,0]
[6,8]
[5,0]
[3,7]
[2,7]
Page 56
ENV 1991-2-5:1997
Table B.3:
Values of T for superstructure group 3
Depth of
slab
(h)
Surfacing
thickness
Positive
temperature
difference
m
0,2
mm
unsurfaced
waterproofed
50
100
150
200
T1
C
[12,0]
[19,5]
[13,2]
[8,5]
[5,6]
[3,7]
T2
C
[5,0]
[8,5]
[4,9]
[3,5]
[2,5]
[2,0]
T3
C
[0,1]
[0,0]
[0,3]
[0,5]
[0,2]
[0,5]
T1
C
[4,7]
[4,7]
[3,1]
[2,0]
[1,1]
[0,5]
T2
C
[1,7]
[1,7]
[1,0]
[0,5]
[0,3]
[0,2]
T3
C
[0,0]
[0,0]
[0,2]
[0,5]
[0,7]
[1,0]
T4
C
[0,7]
[0,7]
[1,2]
[1,5]
[1,7]
[1,8]
0,4
unsurfaced
waterproofed
50
100
150
200
[15,2]
[23,6]
[17,2]
[12,0]
[8,5]
[6,2]
[4,4]
[6,5]
[4,6]
[3,0]
[2,0]
[1,3]
[1,2]
[1,0]
[1,4]
[1,5]
[1,2]
[1,0]
[9,0]
[9,0]
[6,4]
[4,5]
[3,2]
[2,2]
[3,5]
[3,5]
[2,3]
[1,4]
[0,9]
[0,5]
[0,4]
[0,4]
[0,6]
[1,0]
[1,4]
[1,9]
[2,9]
[2,9]
[3,2]
[3,5]
[3,8]
[4,0]
0,6
unsurfaced
waterproofed
50
100
150
200
[15,2]
[23,6]
[17,6]
[13,0]
[9,7]
[7,2]
[4,0]
[6,0]
[4,0]
[3,0]
[2,2]
[1,5]
[1,4]
[1,4]
[1,8]
[2,0]
[1,7]
[1,5]
[11,8]
[11,8]
[8,7]
[6,5]
[4,9]
[3,6]
[4,0]
[4,0]
[2,7]
[1,8]
[1,1]
[0,6]
[0,9]
[0,9]
[1,2]
[1,5]
[1,7]
[1,9]
[4,6]
[4,6]
[4,9]
[5,0]
[5,1]
[5,1]
0,8
unsurfaced
waterproofed
50
100
150
200
[15,4]
[23,6]
[17,8]
[13,5]
[10,0]
[7,5]
[4,0]
[5,0]
[4,0]
[3,0]
[2,5]
[2,1]
[2,0]
[1,4]
[2,1]
[2,5]
[2,0]
[1,5]
[12,8]
[12,8]
[9,8]
[7,6]
[5,8]
[4,5]
[3,3]
[3,3]
[2,4]
[1,7]
[1,3]
[1,0]
[0,9]
[0,9]
[1,2]
[1,5]
[1,7]
[1,9]
[5,6]
[5,6]
[5,8]
[6,0]
[6,2]
[6,0]
1,0
unsurfaced
waterproofed
50
100
150
200
[15,4]
[23,6]
[17,8]
[13,5]
[10,0]
[7,5]
[4,0]
[5,0]
[4,0]
[3,0]
[2,5]
[2,1]
[2,0]
[1,4]
[2,1]
[2,5]
[2,0]
[1,5]
[13,4]
[13,4]
[10,3]
[8,0]
[6,2]
[4,3]
[3,0]
[3,0]
[2,1]
[1,5]
[1,1]
[0,9]
[0,9]
[0,9]
[1,2]
[1,5]
[1,7]
[1,9]
[6,4]
[6,4]
[6,3]
[6,3]
[6,2]
[5,8]
1,5
unsurfaced
waterproofed
50
100
150
200
[15,4]
[23,6]
[17,8]
[13,5]
[10,0]
[7,5]
[4,5]
[5,0]
[4,0]
[3,0]
[2,5]
[2,1]
[2,0]
[1,4]
[2,1]
[2,5]
[2,0]
[1,5]
[13,7]
[13,7]
[10,6]
[8,4]
[6,5]
[5,0]
[1,0]
[1,0]
[0,7]
[0,5]
[0,4]
[0,3]
[0,6]
[0,6]
[0,8]
[1,0]
[1,1]
[1,2]
[6,7]
[6,7]
[6,6]
[6,5]
[6,2]
[5,6]
o
o
Negative
temperature
difference
o
o
o
o
o
Page 57
ENV 1991-2-5:1997
Annex C
(Informative)
Determination of temperature effects in bridge decks
C.1
General
(1) According to the system of Eurocodes characteristic values of variable loads should be
determined for the ultimate limit state (ULS). For thermal actions the characteristic value is
taken as the value having a return period of 50 years.
(2) According to ENV-1-1 and ENV-1-3 three design situations should be considered for the
serviceability limit state (SLS) and three corresponding representative values of loads or
actions should be determined:
– Infrequent
(return period of occurrence is one year);
– Frequent
(return period of occurrence is two weeks);
– Quasi-permanent.
(3) These representative values may be obtained with the help of reduction coefficients ψ,
which, when multiplied by the characteristic value, lead to the level of action with the given
return period.
∆T1' = ψ1' ∆TK
(infrequent value of thermal action)
∆T1 = ψ1 ∆TK
(frequent value of thermal action)
∆T2 = ψ2 ∆TK
(quasi-permanent value of thermal action)
where:
∆TK
is the characteristic value of thermal action.
(4) The following values for the coefficients ψ may be used:
ψ1' = 0,8;
ψ1 = 0,6;
ψ2 = 0,5.
C.2
Calculation of temperature profile through the depth of the bridge deck
(1) The calculation of temperature distribution through bridge decks has been considered by
numerous authors. The profiles presented in annex B have been derived with the help of the
calculation procedure, developed in the United Kingdom which uses a one-dimensional heat
flow model as outlined in various reports.
Page 58
ENV 1991-2-5:1997
C.3
Climatic data
(1) The environmental conditions which have the greatest influence on the temperature of a
bridge are shade air temperature, and radiation (either incoming total solar radiation (TSR) or
outgoing radiation from the deck). Wind speed may also play an important role; this may be
reflected in the value of the heat transfer coefficient used.
(2) Maximum positive temperature difference profiles through bridge decks invariably occur
in the summer therefore data in Europe should typically be gathered for the months of June,
July and August. Maximum negative temperature difference profiles may occur at any time of
year.
(3) Thus for determination of temperature effects in bridge decks the following climatic data
are required:
– shade air temperature;
– solar radiation;
– overnight re-radiation.
(4) These data should be obtained for each country or for each climatic zone if the country
consists of several climatic zones.
(5) In all cases, the period of observations of climatic data should be as long as possible and
ideally, at least 25 years.
C.4
Structural data
(1) The structural arrangement and material used will affect the temperature effects in bridges.
The most important parameters are:
– Geometrical characteristics of bridge cross section;
– Thermal and material properties of the bridge deck such as:
– coefficient of absorptivity;
– coefficient of emissivity;
– heat transfer coefficient at the surfaces;
– thermal conductivity;
– specific heat;
– density.
C.5
Determination of temperature differences
(1) With the use of the above parameters the maxima and minima of the linear temperature
differences may be extracted, using published literature.
(2) For concrete bridge decks the use of a one-dimensional heat flow model is suitable.
Page 59
ENV 1991-2-5:1997
(3) In the case of steel and composite bridge decks a two-dimensional heat flow model may be
required to account for differences across the section.
(4) For composite cross-sections it is necessary to consider the properties of each material and
derive equivalent temperature distributions. This may be done as follows.
Figure C.1:
Composite cross section
(5) With reference of Figures 4.1 and Figure C.1, if:
nE =
E1
E2
(C.1)
α
nα = α 1
2
(C.2)
where:
E1
is Young's modulus of elasticity of material 1;
E2
is Young's modulus of elasticity of material 2;
α1
is the coefficient of thermal linear expansion of material 1;
α2
is the coefficient of thermal linear expansion of material 2;
A1
is the area of the cross-section with material 1;
A2
is the area of the cross-section with material 2.
Page 60
ENV 1991-2-5:1997
the effective uniform temperature component is given by:
n E na
∆TN =
∫∫ T (z, y)dA1 + ∫∫ T (z, y, )dA2
A1
A2
n E A1 + A2
(C.3)
(6) The linear gradient along y-y axis (°C/m), is given by:
n E nα
∫ T (z, y)y dA1 + ∫ T (z, y) y dA2
A1
∆TMy =
A2
n E J z1 + J z 2
(C.4)
where:
Jz1
is the moment of inertia of the area of material 1 with respect of the z central
principal axis of the homogenized cross-section;
Jz2
is the moment of inertia of the area of material 2 with respect of the z central
principal axis of the homogenized cross-section.
(7) The linear gradient along z-z axis (°C/m), is given by:
n E nα
∆TMz =
∫ T (z, y)z dA1 + ∫ T (z, y)z dA2
A1
A2
n E J y1 + J y 2
(C.5)
where:
Jy1
is the moment of inertia of the area of material 1 with respect of the y central
principal axis of the homogenized cross-section,
Jy2
is the moment of inertia of the area of material 1 with respect of the y central
principal axis of the homogenized cross-section.
(8) If the y axis is vertical and the z axis is horizontal then:
∆TMy = H × ∆TMy ; and ∆TMz = H × ∆TMz
where:
H
is the height of cross-section (vertical);
(C.6)
Page 61
ENV 1991-2-5:1997
B
is the width of the cross-section (horizontal).
(9) When T(z,y) is uniform over the cross section, equation (C.4 and C.5) lead nevertheless to
non zero linear vertical or horizontal gradients which are respectively:
n E nα
∆TMy = T
∫ y dA1 + ∫ y dA2
A1
A2
n E J Z1 + J Z 2
n E nα
;
∆TMz = T
∫ z dA1 + ∫ z dA2
A1
A2
n E J y1 + J y 2
(C.7)
and are equal to zero only when nα = 1, that is, when the coefficients of thermal linear
expansion of the two materials are the same.
C.6
Statistical analysis
(1) In order to determine appropriate values of temperature ranges and differences, statistical
analyses need to be undertaken.
Page 62
ENV 1991-2-5:1997
Annex D
(Informative)
Coefficients of linear expansion
(1) For the purpose of the derivation of thermal actions in accordance with this Part, Table
D.1 gives values for the coefficient of linear expansion for a selection of commonly used
materials.
Table D.1: Coefficients of linear expansion
αT (×
×10-6/°C)
Material
Aluminium, aluminium alloy
24
Stainless steel
18
Structural steel, wrought or cast iron
10
Concrete except as under
10
Concrete, limestone aggregate
9
Concrete, lightweight aggregate
7
Masonry
6-10 (see notes)
Glass
(see note 4)
Timber, along grain
5
Timber, against grain
30-70 (see notes)
NOTE 1: For other materials special advice should be sought.
NOTE 2: The values given should be used for the derivation of thermal actions, unless a
lower value can be verified by tests or more detailed studies.
NOTE 3: Values for masonry will vary depending on the type of brickwork; values for
timber against the grain can vary considerably according to the type of timber.
NOTE 4: For more detailed information see:
EN 572-1:
Glass in building - Basic soda lime silicate glass - Part 1:
Definitions and general physical and mechanical properties;
prEN 1748-1:
Glass in building - Special products - Part 1: Borosilicate glasses;
prEN 1748-2:
Glass in building - Special products - Part 2: Glass ceramics.
NOTE 5: For some materials such as masonry and timber, other parameters (e.g. moisture
content) also need to be considered, see ENV 1995 -1996.