TKL 2x4 Installation Instructions - Precision
Transcription
TKL 2x4 Installation Instructions - Precision
TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions Product Information Project Name Type Catalog Number Date INCLUDED MATERIALS A. (1) 2x4 TKL Retrofit Assembly B. (2) Tab Bracket (p/n 95001747-M069) C. (6) #8-18 x 1/2” Self-Drilling Sheet Metal Screw p/n 95000989 SCR 8-18X1/2 HWH SD2 ZN MATERIALS REQUIRED • Wiring Nuts of Appropriate Size and Quantity TOOLS REQUIRED • • • • • Electric driver drill, standard jaw chuck 1/4” hex nutdriver bit Electric wire cutter / stripper Screwdrivers, Phillips and slotted Personal safety equipment ENGLISH - WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY! • • • • • • • • WARNING - Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. WARNING - Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING - This product is sensitive to Electrical Static Discharge (ESD). Care should be taken to avoid direct contact with the LEDs. Installers should be grounded using a wrist strap or other suitable method of grounding. Failure to ground the installer may cause pre-mature failures and void the fixture warranty. Fixture is suitable for damp locations. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. FRANÇAIS - MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT! • • • • • • • • AVERTISSEMENT - Risque d'incendie ou de choc électrique. Câblage du luminaire et pièces électriques peuvent être endommagés lors du perçage pour l'installation du kit de conversion à DEL. Vérifier le câblage et les composants intérieur. AVERTISSEMENT - Risque d'incendie ou de choc électrique. Installation du Kit d'adaptation DEL nécessite la connaissance des systèmes électriques des luminaires. Si non qualifié, ne essayez pas l'installation. Contactez un électricien qualifié. AVERTISSEMENT - Risque d'incendie ou de choc électrique. Installez ce kit dans les luminaires qui ont les caractéristiques de construction et dimensions indiquées dans les photographies et/ou dessins. Seuls les trous ouverts indiqués dans les photographies et/ ou dessins peuvent être effectués ou modifiés à la suite de l'installation du kit. Ne laissez pas d'autres trous ouverts dans un ensemble de câblage ou de composants électriques. AVERTISSEMENT - Pour éviter d'endommager le câblage ou l'abrasion, ne pas exposer le câblage aux bords ou d'autres objets pointus. AVERTISSEMENT - Ce produit est sensible aux décharges d'électricité statique (ES). Des précautions doivent être prises pour éviter le contact direct avec les DEL. Les installateurs doivent être mis à la terre en utilisant un bracelet ou une autre méthode appropriée de mise à la terre. Defaut de mécanisme à la terre le programme d'installation peut provoquer des défaillances prématurées et annuler la garantie du luminaire. Luminaire est adapté aux endroits humides. LE KIT DE MODIFICATION EST ACCEPTÉ COMME UNE COMPOSANTE D'UN LUMINAIRE OÙ LA PERTINENCE DE LA COMBINAISON DOIT ÊTRE DÉTERMINÉE PAR LA CSA OU LES AUTORITÉS AYANT JURIDICTION. Page 1/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions INSTALLATION INSTRUCTIONS 1. To avoid the possibility of electric shock, turn off power. 2. Open the troffer and remove existing lamps, lamp mounts, ballasts / drivers, interconnection components, etc. (Fig. 1) Fig. 1 3. Using the #8 self-drilling sheet metal screws, install the 2 Tab Brackets in the center of each short side of the troffer, against the troffer’s end caps (Figs. 2, 3, 4). Fig. 2 The Tab Brackets should be positioned up against the opposite ends of the troffer, and centered to within +/- 1/8” of the troffer’s centerline. Fig. 3 4. (View looking upward into the troffer, after the Tab Brackets have been installed - Fig. 4) Fig. 4 Page 2/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions INSTALLATION INSTRUCTIONS 5. Bring the TKL Retrofit Assembly up to the troffer. Locate the safety cables at each end of the Retrofit Assembly (Fig. 5). Safety Cables Fig. 5 6. Using 2 of the self-drilling sheet metal screws, secure the safety cables to the troffer body (Figures 6 and 7): Fig. 6 Fig. 7 Page 3/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions INSTALLATION INSTRUCTIONS 7. Fasten the service cable’s ground wire to the ground lead of the TKL Retrofit Assembly (Figure 8). 8. Connect the input service cable’s voltage supply wires to the TKL Retrofit Assembly. TKL ground lead Fig. 8 9. Lift the TKL Retrofit Assembly up into the troffer enclosure (Fig 9). 10.To secure the TKL Retrofit Assembly to the Tab Brackets, engage the Retrofit Assembly’s slots into the Tab Bracket’s tabs one side at the time, as shown in Figures 10 and 11. Fig. 9 Fig. 10 Slide the Retrofit Assembly sideways, such that one of its slots engages their tabs, as shown. Page 4/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions INSTALLATION INSTRUCTIONS 10.Continued from previous page. Then, pinch together the Gear Tray’s central channel, such that the other set of slots can engage their tabs. Fig. 11 11.Connect the leads which are labeled “Emergency Battery.” This will connect the emergency battery, causing the LEDs to turn on (even though line power has not yet been energized). 12.Close and secure the lens door (Fig. 12). 13.Carefully check all mechanical and electrical connections. 14.Installation Complete. Apply power to the fixture. Fig. 12 Page 5/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com 13.81" 2.07" TKL LED Prismatic Troffer Conversion Kit 2x4 Installation Instructions 23.00" Minimum Required Opening in Existing Fixture MINIMUM DIMENSIONS OF EXISTING FIXTURE OPENING 2X4 TKL CROSS SECTION & SIDE VIEW 13.81" 2.08" 46.69" Minimum Required Opening in Existing Fixture *Drawings N.T.S. FIT AND FUNCTION Minimum dimensional requirements are above but Precision-Paragon[P2] recommends a trial installation prior to ordering project quantities. TKL Coversion Kits are designed to fit into most lensed-recessed prismatic troffers mounted in T-grid installation. Page 6/6 - Revised 03/25/15 © 2015 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
Documents pareils
SLK Installation Guide
wiring and electrical parts may be damaged when
drilling for installation of LED retrofit kit. Check
for enclosed wiring and components.
WARNING - Risk of fire or electric shock. LED Retrofit
Kit i...