Easy Programming using WindLGC Online test and simulation
Transcription
Easy Programming using WindLGC Online test and simulation
Easy Programming using WindLGC Online test and simulation mode allows convenient programming Programming Software for IDEC SmartRelay Enhanced functions in WindLGC such as offline simulation and online testing of programs greatly reduces programming time. Simulation Online Test Function Block only! Wiring status and function block parameters can be confirmed by simulating on the WindLGC programming screen. Simulation is possible for every scan or for a predetermined period of time. When WindLGC is connected to the IDEC SmartRelay installed in a control panel or equipment, the I/O statuses can be monitored on the WindLGC screen. Downloading user programs and testing operations greatly facilitate maintenance. Update Center http://www.idec.com/english/download/ Digital outputs can be turned on or off independently. Useful for confirming operation of subsequent programs. Compare When adding or modifying a part of the user program, this function makes it possible to compare two programs on the WindLGC screen. Create function block and ladder diagrams using simple drag and drop functions Function Block Programming Free upgrade from WindLGC Ver. 3 can be downloaded from the update center or IDEC website through the Internet. Set Output Function block parameters are entered and modified in the function block dialog boxes. Ladder Programming In addition to function block diagrams, WindLGC can program ladder diagrams for the IDEC SmartRelay. When downloading the user program to the base module, ladder diagrams are converted into function block diagrams. For details, see the user’s manual and FAQ available at the following website. Ver. 5 System Requirements CPU Pentium III 500 MHz or higher OS Windows XP/2000/98/95/Me/NT4.0 Hard disk space 90 MB 8 RAM 128 MB Display 800 × 600 pixels, 256 colors (1024 × 768 recommended) http://www.idec.com/faq/en/controller/ Programming Software General Function Blocks: 8 Special Function Blocks: 28 General Function Blocks • AND & 3 4 5 6 7 8 9 10 2 Trg Par TH T & 3 4 5 6 Q TL Q T 7 8 9 10 Edge detection with edge evaluation (pos. edge) S R Q 1 2 3 4 RS Parallel connection of normally open contacts Trg Series connection of normally closed contacts Sa Su ON 12:00 OFF 20:00 Su ON 8:00 OFF 22:00 No1 No2 Q TH TL TH Q T 1s T Starts Q 12 20 12 20 8 12 20 8 MM.DDt Double changeover contact Q =1 Q Q Trg TL TL Q TIL T1 T En 22 20 Switch No1 No2 No3 Q No 25 R Cnt Dir 3 Par 21 MM DD Q R Cnt Dir Par Q S1 S2 S3 S4 S5 S6 S7 S8 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 Ax Par Demo Version A Q 1 1 0 1 0 0 0 1 Dir 1 Max SP PV Min 2 3 Mq En Ax Par MN=0 OT Ax Par AQ In Trg Dir Par Q A/M R PV Par AQ En Sel St Par AQ En S1 S2 Par AQ AQ 500 ms Q En Sel St MaxL Level 2 Level 1 StSp+B R En Ral Par Q • Analog ramp control Ra te Ra te Ra te Ra te AQ 100 ms • Operating hours counter R En Ral Q MN=MI En Par S4=Q (Example) B http://www.idec.com/english/download/ Q Shift Down Q Download 0 1 1 0 1 0 0 0 A/M R /+ Q • Analog value monitoring E 1 1 0 1 0 0 0 0 • PI controller AX Q n Aen+ Aen AenX 1 0 1 0 0 0 0 1 Shift Up o n AX Q En P Par • Shift register In Trg Q Dir OFF=On+ OFF=On+ Q Q • Analog differential trigger Q Trg R Par • Analog amplifier Q Connection of closed contact Q • Message texts Q • Up/down counter • NOT 1 Trg Par • Dual-function switch Par Fed. Mar. Apr. 25 0 1 Q 15s Su No 02.25 No 04.15 1 2 Ax Ay Par Trg • Twelve-month time switch • XOR Q • Stairwell light switch Q • Softkey 1 Ax Par tor =200 Trg R Q Sa 1 2 3 4 Q Q -200 Trg Par T A/2 0 A/1-A/2 0 S R Par RS TL A/1 or 0 A/2 1000 200 • Seven-day time switch • NOR Fre Par A/1 0 • Interval time-delay relay/ Pulse output Q 1s 1000 Q • Edge-triggered interval time-delay relay 1 fa=3Hz 1s • Analog comparator Trg S R Q • OR fa=5Hz Q Par Trg Q Fre G-T Q 1000 S R Q Trg Q Q TL 1000 SW SW Trg R Par • Current impulse relay 1 2 & 3 4 En Par • Analog trigger • Latching relay NAND 1 Trg • Retentive on-delay • NAND (Edge) Cycle TH Trg R Q I1 I2 I3 I4 Q Q T Starts • Frequency trigger Q Q 1 2 3 4 Q Trg Q • On-/Off-delay • NAND TL En Inv Par • Random generator Trg R Par T 1 2 & 3 4 En Inv Q TH • Off-delay Edge detection with edge evaluation (pos. edge) Parallel connection of normally closed contacts Q T Trg R Q I1 I2 I3 I4 Q 2 Q Q AND 1 Trg Par Trg • AND (Edge) Cycle • Asynchronous pulse generator • On-delay 1 2 3 4 Series connection of normally open contacts Special Function Blocks 100 ms 100 ms • Analog multiplexer h Q En S1 S2 V1 V2 V3 0 V4 AQ 9
Documents pareils
keyword bid management
topography and context of the place where it is deployed (organizational layout, network
topography, stakeholders location), therefore it must adapt to this information landscape and change
with it...